• EN 50168:1994

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Sectional specification for work area wiring cables with a common overall screen for use in digital communication

    Available format(s): 

    Superseded date:  01-02-2001

    Language(s): 

    Published date:  07-10-1994

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Guide to use
        1.1 Scope
        1.2 Introduction
        1.3 Installation considerations
        1.4 Object
    2 Definitions and requirements
        2.1 General
        2.2 Reference publications
        2.3 Definitions
        2.4 Materials and cable construction
             2.4.1 General
             2.4.2 Cable construction
             2.4.3 Conductor
             2.4.4 Insulation
             2.4.5 Cable element
             2.4.6 Screening of the cable element
             2.4.7 Colour code of insulation
             2.4.8 Cable make up
             2.4.9 Screening of the cable core
             2.4.10 Sheath
             2.4.11 Colour of sheath
             2.4.12 Identification
             2.4.13 Finished cable
             2.4.14 Cable overall diameter
    3 Characteristics and requirements
        3.1 General
        3.2 Electrical tests
             3.2.1 Conductor resistance
             3.2.2 Resistance unbalance
             3.2.3 Dielectric strength
             3.2.4 Insulation resistance
             3.2.5 Mutual capacitance
             3.2.6 Capacitance unbalance
             3.2.7 Transfer impedance
        3.3 Transmission characteristics
             3.3.2 Attenuation
             3.3.3 Unbalance attenuation
             3.3.4 Near end crosstalk
             3.3.5 Far end crosstalk
             3.3.6 Characteristics impedance
             3.3.7 Structural Return Loss (SRL)
             3.3.8 Longitudinal to Differential Conversion
                    Loss (LCL)
        3.4 Mechanical and dimension characteristics and
             requirements
             3.4.1 Dimensional requirements
             3.4.2 Elongation at break of conductors
             3.4.3 Elongation and tensile strength at break
                    of the insulation
             3.4.4 Elongation and tensile strength at break
                    of sheath
             3.4.5 Crushing of the cable
             3.4.6 Impact test on the cable
             3.4.7 Repeated bending of the cable
             3.4.8 Tensile performance of the cable
        3.5 Environmental characteristics
             3.5.1 Shrinkage of insulation
             3.5.2 Wrapping of insulation after thermal
                    ageing
             3.5.3 Bending of insulation at low temperature
             3.5.4 Elongation and tensile strength at break
                    of the sheath after ageing
             3.5.5 Sheath pressure test at high temperature
             3.5.6 Cold bend of the cable
             3.5.7 Heat shock
             3.5.8 Flame propagation characteristics
                    of single cable
             3.5.9 Flame propagation characteristics of
                    bunched cables
             3.5.10 Acid gas evolution
             3.5.11 Smoke generation
             3.5.12 Toxic gas emission
    4 Quality assessement procedures
    Annex A (informative) Attentuation and NEXT

    Abstract - (Show below) - (Hide below)

    This standard refers to HD 608 S1:1992, Generic specification for symmetrical pair/quad or multicore cables for digital communications. It covers individually screened pair(s) or quad(s) in cables for work area wiring. The cables shall be provided with a common overall screen. These cables are suitable for different communication systems to which reference is made in detail specifications. The cables covered by this specification are intended to operate with voltages and currents normally adopted for communication systems. These cables shall not be connected to low impedance sources, for example, the public mains electricity supply. The cables specified in this standard shall meet the requirements of the Generic Specification. This sectional specification may be supplemented with specific specifications given additional information if required by a particular application (e.g. regarding safety and reliability conditions)

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 46X
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective