• EN 50270:2015

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen

    Available format(s): 

    Superseded date:  25-11-2019

    Language(s): 

    Published date:  16-01-2015

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms and Definitions
    4 EMC test plan
    5 Immunity tests
    6 Emission tests
    7 Test report
    8 Modifications
    Annex ZZ (informative) - Coverage of Essential
             Requirements of EU Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen which are subject to the performance standards for gas detection apparatus, for example EN 45544 (all parts), EN 50104, EN 50194 (all parts), EN 50291, EN 50379 (all parts), EN 50543, EN 50545, EN 60079-29-1 or EN 60079-29-4.NOTEFor the purpose of this standard the word ‘toxic’ covers ‘very toxic’, ‘toxic’, ‘harmful’, ‘corrosive‘, ‘irritating‘, ‘sensitising‘, ‘carcinogenic‘, ‘mutagenic‘ and ‘teratogenic‘.This European Standard applies to apparatus intended for use in residential, commercial and light-industrial environments as well as to apparatus intended for use in industrial environments. The apparatus may be AC-, DC- or battery powered.This European Standard is also applicable to apparatus which is intended for use in hazardous areas which may contain explosive or potentially explosive atmospheres. It covers only normal operation and does not cover safety requirements related to EMC phenomena.This standard is a product standard which is based on the product family standard EN 61326-1. This product standard takes precedence over the product family standard and over generic standards.This standard applies to electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen that include functions specified by the manufacturer as being safety functions and can include functions specified as not being safety functions.All performance standards for the detection and measurement of combustible gases, toxic gases or oxygen include the minimum requirements for functional safety specified in EN 50271. There are also gas detectors and gas detection systems which are intended to be used with safety integrity levels SIL 1 to SIL 3 according to EN 50402 and EN 61508. For functional safety in industrial applications, this standard has taken into account those aspects of EN 61326–3–2 relating to the measuring and warning function of the apparatus defined as safety function.Apparatus of type 1 where the manufacturer claims a safety integrity level should be considered as type 2 apparatus with regard to immunity requirements.This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges, and also for emission tests. The test requirements are specified for each port considered.Apparatus falling within the scope of this European Standard is classified as follows by the following types.Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 61000-6-1 and EN 61000-6-3.Type 2: apparatus intended for use in industrial environments, as described in EN 61000-6-2 and EN 61000-6-4.This European Standard does not apply to any of the following:apparatus intended for the detection of dusts or mists in air;scientific or laboratory based apparatus used only for analysis or measurement;apparatus used exclusively for process measurement purposes;apparatus for medical purposes;apparatus used for breath alcohol measurementapparatus intended for the direct measurement of automotive exhaust gases.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 31
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    13/30276476 DC : 0 BS EN 45544-3 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION
    BS EN 50543:2011 Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air. Requirements and test methods
    BS EN 50379-2:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in statutory inspections and assessment
    BS EN 50104:2010 Electrical apparatus for the detection and measurement of oxygen. Performance requirements and test methods
    BS EN 45544-3:2015 Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours Performance requirements for apparatus used for general gas detection
    UNE-EN 50194-2:2007 Electrical apparatus for the detection of combustible gases in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises - Additional test methods and performance requirements
    BS EN 50291:2001 Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements
    PREN 45544-2 : DRAFT 2013 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MANAGEMENT
    BS 7927:1998 Heating appliances for domestic applications. Portable apparatus designed to detect and measure specific combustion flue gas products. Requirements
    08/30176065 DC : DRAFT JAN 2008 BS EN 50194-1 - ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    CEI EN 50379-3 : 2012 SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN NON-STATUTORY SERVICING OF GAS FIRED HEATING APPLIANCES
    BS ISO 16000-29:2014 Indoor air Test methods for VOC detectors
    BS EN 45544-1:2015 Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours General requirements and test methods
    BS EN 50194:2000 Electrical apparatus for the detection of combustible gases in domestic premises. Test methods and performance requirements
    DIN EN 50402 : 2018 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS
    CEI EN 50291 : 2002 ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES TEST METHODS AND PERFORMANCE REQUIREMENTS
    CEI EN 50104 : 2011 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF OXYGEN - PERFORMANCE REQUIREMENTS AND TEST METHODS
    I.S. EN 50402:2017 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS
    BS EN 50291-1 : 2010 ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    BS EN 50545-1 : 2011 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
    UNE-EN 50543:2011 Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air - Requirements and test methods
    CEI EN 50379-1 : 2012 SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    PREN 45544-3 : DRAFT 2013 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION
    CEI EN 60079-29-4 : 2011 EXPLOSIVE ATMOSPHERES - PART 29-4: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF OPEN PATH DETECTORS FOR FLAMMABLE GASES
    UNE-EN 50379-1:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods
    I.S. EN 61779-1:2003 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    VDE 0400-70 : 2018 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS
    I.S. EN 50545-1:2011 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
    BS EN 50291-2:2010 Electrical apparatus for the detection of carbon monoxide in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft. Additional test methods and performance requirements
    EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
    EN 50379-1:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods
    (INVALID RECORD) EN 50543:2011/AC:2011 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    EN 60079-29-4:2010 Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
    EN 50291:2001 Electrical apparatus for the detection of carbon monoxide in domestic premises - Test methods and performance requirements
    EN 50241-2:1999 Specification for open path apparatus for the detection of combustible or toxic gases and vapours - Part 2: Performance requirements for apparatus for the detection of combustible gases
    OVE/ONORM EN 60079-29-1 : 2008 EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES
    CEI EN 50543 : 2011 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    NF EN 50194 : 2000 CORR 1 2000 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - TEST METHODS AND PERFORMANCE REQUIREMENTS
    02/203341 DC : DRAFT FEB 2002 PREN 50379-1 - SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    EN 60079-29-1:2016 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
    BS EN 50402:2017 Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen. Requirements on the functional safety of gas detection systems
    CEI 216-8 : 2005 FLUSH-TYPE DETECTORS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - TEST METHODS AND PERFORMANCE REQUIREMENTS
    UNE-EN 60079-29-4:2011 Explosive atmospheres -- Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
    UNE-EN 50104:2011 Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods
    PREN 50402 : DRAFT 2013 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS
    CEI UNI EN 50194 : 2001 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - TEST METHODS AND PERFORMANCE REQUIREMENTS
    CEI 216-5/1 : 2002 ELECTRICAL EQUIPMENT FOR THE DETECTION AND THE MEASUREMENT OF BURNING VAPOURS OR GASES OR TOXIC AND OF OXYGEN FOR CONTINUOUS OPERATION IN FIXED INSTALLATIONS IN NON-HAZARDOUS AREAS - PART 1:GENERAL REQUIREMENTS AND TEST METHODS FOR CONTROL BOARDS AND CONTROL AND SIGNALLING BOARDS
    EN 50402:2017 Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems
    I.S. EN 50194-2:2006 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS
    UNE-EN 60079-29-1:2017 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
    UNE-EN 50291-1:2011 Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements
    ISA 92.00.01 : 2010(R2015) PERFORMANCE REQUIREMENTS FOR TOXIC GAS DETECTORS
    I.S. EN 45544-2:2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT
    I.S. EN 50104:2010 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF OXYGEN - PERFORMANCE REQUIREMENTS AND TEST METHODS
    BS EN 50194-2 : 2006 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS
    NF EN 50545-1 : 2012 AMD 1 2016 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
    CEI UNI EN 50194-1 : 2012 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    NF EN 50291-1 : 2010 AMD 1 2012 ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    EN 50291-1:2018 Gas detectors - Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements
    FM 6320 : 2018 COMBUSTIBLE GAS DETECTORS
    EN 45544-1:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 1: General requirements and test methods
    VDI 4206 Blatt 1:2010-08 Performance criteria and test procedures for measuring devices for monitoring emissions at firing installations - Measuring devices for the determination of gaseous emissions and flue gas parameters
    VDE 0400-40-1 : 2000 AMD 1 2004 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    VDI 4206 Blatt 4:2013-08 Performance criteria and test procedures for measuring devices for monitoring emissions at small firing installations - Measuring devices for the determination of moisture of lumpy wood
    DIN EN 61779-1 : 2001 AMD 11 2004 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    VDE 0400-40-2 : 2000 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES
    13/30275012 DC : 0 BS EN 45544-1 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    DIN EN 50241-1 : 2000 AMD 1 2004 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    UNI CEI EN 50194-1 : 2010 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    EN 303 446-2 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
    PREN 50543 : DRAFT 2009 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    06/30150303 DC : DRAFT MAY 2006 EN 50291-1 - ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    DIN EN 50241-2 : 2000 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES
    13/30260728 DC : 0 BS EN 50402 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS
    09/30214233 DC : 0 BS EN 50543 - ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    13/30276473 DC : 0 BS EN 45544-2 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MANAGEMENT
    BS EN 50241-1:1999 Specification for open path apparatus for the detection of combustible or toxic gases and vapours General requirements and test methods
    CEI EN 50379-2 : 2012 SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT
    02/203342 DC : DRAFT FEB 2002 PREN 50379-2 - SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT
    I.S. EN 50291-1:2010 GAS DETECTORS - ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    BS EN 60079-29-4:2010 Explosive atmospheres Gas detectors. Performance requirements of open path detectors for flammable gases
    BS EN 60079-29-1:2007 Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases
    I.S. EN 50543:2011 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    I.S. EN 50241-2:1999 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES
    UNE-EN 50291-2:2011 Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements
    EN 45544-3:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 3: Performance requirements for apparatus used for general gas detection
    EN 50241-1 : 99 AMD 1 2004 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    EN 45544-2:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 2: Performance requirements for apparatus used for exposure measurement
    NF EN 50543 : 2011 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    BS EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
    DIN ISO 16000-29:2015-02 INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014)
    BS EN 45544-2:2015 Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours Performance requirements for apparatus used for exposure measurement
    08/30184950 DC : DRAFT JULY 2008 BS EN 50291-1 - ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    UNE-EN 50545-1:2012 Electrical apparatus for the detection and measurement of toxic and combustible gases in car parks and tunnels - Part 1: General performance requirements and test methods for the detection and measurement of carbon monoxide and nitrogen oxides
    BS EN 50241-2:1999 Specification for open path apparatus for the detection of combustible or toxic gases and vapours Performance requirements for apparatus for the detection of combustible gases
    CEI 216-5/3 : 2002 ELECTRICAL EQUIPMENT FOR THE DETECTION AND THE MEASUREMENT OF FLAMMABLE VAPOURS OR GASES OR TOXIC AND OF OXYGEN FOR CONTINUOUS OPERATION IN FIXED INSTALLATIONS IN NON-HAZARDOUS AREAS - PART 3:GENERAL REQUIREMENTS AND TEST METHODS FOR DETECTORS OF GASES AND FLAMMABLE VAPOURS WITH PROPORTIONAL OUTPUTS
    BS EN 50379-1:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances General requirements and test methods
    I.S. EN 45544-1:2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    UNE-EN 50379-2:2013 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment
    CEI EN 50291-2 : 2011 ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES INCLUDING RECREATIONAL CRAFT - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS
    I.S. EN 50379-2:2012 SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT
    I.S. EN 50194-1:2009 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS
    I.S. EN 50379-3:2012 SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN NON-STATUTORY SERVICING OF GAS FIRED HEATING APPLIANCES
    I.S. EN 45544-3:2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION
    I.S. EN 50379-1:2012 SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    UNE-EN 50379-3:2013 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
    DIN ISO 16000-29 E : 2015 INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014)
    BS EN 50194-1:2009 Electrical apparatus for the detection of combustible gases in domestic premises Test methods and performance requirements
    02/203343 DC : DRAFT FEB 2002 PREN 50379-3 - SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN NON-STATUTORY SERVICING OF GAS FIRED HEATING APPLIANCES
    BS EN 61779-1:2000 Electrical apparatus for the detection and measurement of flammable gases General requirements and test methods
    I.S. EN 60079-29-1:2016 EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES
    CEI 216-5/2 : 2002 ELECTRICAL EQUIPMENT FOR THE DETECTION AND THE MEASUREMENT OF BURNING VAPOURS OR GASES OR TOXIC AND OF OXYGEN FOR CONTINUOUS OPERATION IN FIXED INSTALLATIONS IN NON-HAZARDOUS AREAS PART 2:GENERAL REQUIREMENTS AND TEST METHODS FOR DETECTORS OF GASES AND FLAMMABLE VAPOURS WITH ONE OR MORE FIXED ALARM LEVELS
    NF EN 60079-29-4 : 2010 EXPLOSIVE ATMOSPHERES - PART 29-4: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF OPEN PATH DETECTORS FOR FLAMMABLE GASES
    I.S. EN 50291-2:2010 ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES INCLUDING RECREATIONAL CRAFT - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS
    ISO 16000-29:2014 Indoor air Part 29: Test methods for VOC detectors
    I.S. EN 60079-29-4:2010 EXPLOSIVE ATMOSPHERES - PART 29-4: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF OPEN PATH DETECTORS FOR FLAMMABLE GASES
    I.S. EN 50241-1:1999 SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - GENERAL REQUIREMENTS AND TEST METHODS
    EN 50379-2:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment
    EN 61779-1 : 2000 AMD 11 2004 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    EN 50104:2010 Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods
    EN 45544-1:2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    EN 45544-2 : 2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT
    EN 50194:2000 Electrical apparatus for the detection of combustible gases in domestic premises - Part 1: Test methods and performance requirements
    EN 50194-2 : 2006 AMD 1 2016 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS
    EN 45544-3 : 2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION
    EN 50291-2:2010 Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements
    EN 50194-1:2009 Electrical apparatus for the detection of combustible gases in domestic premises - Part 1: Test methods and performance requirements
    EN 50545-1:2011/A1:2016 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    EN 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements
    EN 50104:2010 Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods
    EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
    IEC 61000-6-4:2006+AMD1:2010 CSV ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
    EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
    IEC 61326-3-2:2017 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
    EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
    EN 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements
    EN 60079-29-4:2010 Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
    EN 45544-3 : 2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
    EN 45544-1:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 1: General requirements and test methods
    EN 60079-29-1:2016 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
    EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61326-3-2 : 2.0 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
    IEC 61000-6-1 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS
    EN 50194-2 : 2006 AMD 1 2016 ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS
    EN 50379-2:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508)
    IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
    IEC 60079-29-4:2009 Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
    EN 50291-2:2010 Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    EN 50402:2017 Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    EN 45544-2:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 2: Performance requirements for apparatus used for exposure measurement
    EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
    EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
    IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    EN 50545-1:2011/A1:2016 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
    EN 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems
    (INVALID RECORD) EN 50543:2011/AC:2011 ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS
    EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
    EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    EN 50271:2010 Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies
    EN 45544-1:2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
    IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
    EN 50379-1:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods
    EN 50194-1:2009 Electrical apparatus for the detection of combustible gases in domestic premises - Part 1: Test methods and performance requirements
    EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
    EN 45544-3:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 3: Performance requirements for apparatus used for general gas detection
    EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
    IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
    IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508)
    EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
    EN 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations
    EN 45544-2 : 2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective