• EN 50289-3-4:2001

    Current The latest, up-to-date edition.

    Communication cables - Specifications for test methods - Part 3-4: Mechanical test methods - Tensile strength, elongation and shrinkage of insulation and sheath

    Available format(s): 

    Language(s): 

    Published date:  20-08-2001

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 Test values
    5 Applicability
    6 Pre-conditioning
    7 Test temperature
    8 Elongation
    9 Tensile strength
    10 Shrinkage
       10.1 Sampling
       10.2 Procedure
       10.3 Expression of results
    11 Test report

    Abstract - (Show below) - (Hide below)

    This Part 3-4 of EN 50289 details the method of test to determine the tensile strength, elongation and shrinkage of insulation and sheath of cables used in analogue and digital communication systems.It is to be read in conjunction with Part 3-1 of EN 50289, which contains essential provisions for its application.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 46X
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    PREN 50288-11-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    BS EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables characterised up to 500 MHz. Horizontal and building backbone cables
    10/30216201 DC : 0 BS EN 50882-11 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERISED UP TO 500 MHZ, FOR HORIZONTAL AND BUILDING BACKBONE WIRING
    BS EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
    PREN 50288-9-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
    I.S. EN 50288-11-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
    I.S. EN 50288-10-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
    I.S. EN 50288-8:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
    EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
    EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 9-2: Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
    EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
    10/30216235 DC : 0 BS EN 50288-10 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    13/30277706 DC : 0 BS EN 50288-11-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    BS EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
    BS EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
    08/30165949 DC : DRAFT JULY 2008 BS EN 50288-8 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
    PREN 50288-10 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    PREN 50288-9-1 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    UNE-EN 50288-11-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
    I.S. EN 50288-9-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
    BS EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control Specification for type 1 cables characterised up to 2 MHz
    BS EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterised up to 1 000 MHz. Horizontal and building backbone cables
    UNE-EN 50288-10-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
    I.S. EN 50288-9-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    I.S. EN 50288-10-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL FLOOR AND BUILDING BACKBONE CABLES
    UNE-EN 50288-8:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz
    13/30260675 DC : 0 BS EN 50288-10-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    13/30260672 DC : 0 BS EN 50288-9-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
    BS EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized up to 500 MHz. Horizontal floor and building backbone cables
    I.S. EN 50288-11-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-1: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERISED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    PREN 50288-10-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    10/30216188 DC : 0 BS EN 50288-9-1 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
    UNE-EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
    UNE-EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
    UNE-EN 50288-9-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
    EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
    EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
    EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
    EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50289-3-1:2001 Communication cables - Specifications for test methods - Part 3-1: Mechanical test methods - General requirements
    EN 50290-1-2:2004 Communication cables - Part 1-2: Definitions
    EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective