• There are no items in your cart

EN 50289-3-9:2001

Current

Current

The latest, up-to-date edition.

Communication cables - Specifications for test methods - Part 3-9: Mechanical test methods - Bending tests

Published date

28-08-2001

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Single bending
    4.1 Equipment
    4.2 Test sample
        4.2.1 Optical cables
        4.2.2 Coaxial cables
        4.2.3 Symmetrical cables
    4.3 Procedure
        4.3.1 Procedure 1
        4.3.2 Procedure 2
    4.4 Requirements
    4.5 Test report
5 Repeated bending
    5.1 Equipment
    5.2 Test sample
        5.2.1 Sample length
        5.2.2 Termination
    5.3 Procedure
    5.4 Requirements
    5.5 Test report
6 Flexing
    6.1 Equipment
    6.2 Test sample
    6.3 Procedure
    6.4 Requirements
    6.5 Test report
7 Flexing endurance
    7.1 Equipment
    7.2 Test sample
    7.3 Procedure
    7.4 Requirements
    7.5 Test report
8 Cable bending under tension (dynamic test)
    8.1 Equipment
    8.2 Test sample
    8.3 Procedure
        8.3.1 Procedure 1
        8.3.2 Procedure 2
    8.4 Requirements
    8.5 Test report
9 Stiffness
    9.1 Introduction
    9.2 Equipment
        9.2.1 Method A
        9.2.2 Method B
        9.2.3 Method C
    9.3 Test sample
    9.4 Procedure
        9.4.1 Method A
        9.4.2 Method B
        9.4.3 Method C
    9.5 Requirements
    9.6 Test report
10 Kink test
    10.1 Sample
    10.2 Equipment
    10.3 Procedure
    10.4 Requirement
    10.5 Test report

This Part 3-9 of EN 50289 details the methods of test to determine the bending tests used in analogue and digital communication systems to:-bending around a test mandrel (clause 4);-repeated bending (clause 5);-repeated flexing in service (clause 6);-flexing in service (clause 7);-bending around rollers or bows during installation (clause 8); and-measure the stiffness (clause 9) of such a cable;-kink test (clause 10).It is to be read in conjunction with Part 3-1 of EN 50289, which contains essential provisions for its application.

Committee
CLC/TC 46X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN 50441-1:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
15/30332390 DC : 0 BS EN 50117-10-1 - COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
PREN 50290-4-2 : DRAFT 2013 COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
PREN 50288-11-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
15/30332399 DC : 0 BS EN 50117-11-2 - COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ
10/30215871 DC : 0 BS EN 50441-4 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
BS EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables characterised up to 500 MHz. Horizontal and building backbone cables
BS EN 50441-3:2006 Cables for indoor residential telecommunication installations Screened cables. Grade 3
10/30216201 DC : 0 BS EN 50882-11 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERISED UP TO 500 MHZ, FOR HORIZONTAL AND BUILDING BACKBONE WIRING
BS EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
07/30169496 DC : 0 EN 50117-4-1 - COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
10/30215867 DC : 0 BS EN 50441-2 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
PREN 50288-9-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
I.S. EN 50117-4-2:2015 COAXIAL CABLES - PART 4-2: SECTIONAL SPECIFICATION FOR CATV CABLES UP TO 6 GHZ USED IN CABLED DISTRIBUTION NETWORKS
I.S. EN 50288-11-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50441-4:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
I.S. EN 50288-10-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50117-2-3:2004 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
CEI EN 50441-2 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
I.S. EN 50288-8:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
EN 50117-2-2:2004/A2:2013 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
EN 50441-3:2006 Cables for indoor residential telecommunication installations - Part 3: Screened cables - Grade 3
EN 50290-2-37:2016 Communication cables - Part 2-37: Common design rules and construction - Polyethylene insulation for coaxial cables
EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
EN 50117-4-1 : 2008 AMD 1 2013 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
EN 50441-4:2012 Cables for indoor residential telecommunication installations - Part 4: Cables up to 1 200 MHz - Grade 3
EN 50441-1:2012 Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1
EN 50117-2-4 : 2004 AMD 2 2013 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 9-2: Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
EN 50117-2-5:2004/A2:2013 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
10/30216235 DC : 0 BS EN 50288-10 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50441-4:2012 Cables for indoor residential telecommunication installations Cables up to 1 200 MHz. Grade 3
14/30296669 DC : 0 BS EN 50117-4-2 - COAXIAL CABLES - PART 4-2: SECTIONAL SPECIFICATION FOR CATV CABLES UP TO 6 GHZ USED IN CABLES DISTRIBUTION NETWORKS
BS EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
04/30117159 DC : DRAFT JUL 2004 EN 50441-2 - SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: GRADE 2
UNE-EN 50117-4-1:2010 Coaxial cables - Part 4-1: Sectional specification for cables for BCT cabling in accordance with EN 50173 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz
17/30350080 DC : 0 BS EN 50441-5 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 5: CABLES UP TO 2200 MHZ FOR ONE PAIR AND REMAINING PAIRS UP TO 1000 MHZ
15/30332369 DC : 0 BS EN 50117-9-1 - COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
CEI EN 50441-3 : 2006 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 3: SCREENED CABLES - GRADE 3
08/30165949 DC : DRAFT JULY 2008 BS EN 50288-8 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
BS EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
PREN 50288-10 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
PREN 50288-9-1 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
CEI EN 50173-1 : 2011 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS
UNE-EN 50117-4-2:2015 Coaxial cables - Part 4-2: Sectional specification for CATV cables up to 6 GHz used in cabled distribution networks
PREN 50441-4 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
UNE-EN 50288-11-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
CEI EN 50290-2-37 : 1ED 2017 COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
I.S. EN 50288-9-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
CEI EN 50290-2-38 : 1ED 2017 COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION FOR COAXIAL CABLES
15/30332393 DC : 0 BS EN 50117-10-2 - COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
PREN 50441-2 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
BS EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control Specification for type 1 cables characterised up to 2 MHz
BS EN 50290-4-2:2014 Communication cables General considerations for the use of cables. Guide to use
BS EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterised up to 1 000 MHz. Horizontal and building backbone cables
BS EN 50290-2-38:2016 Communication cables Common design rules and construction. Polypropylene insulation for coaxial cables
13/30293741 DC : 0 BS EN 50290-2-37 - COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
10/30215863 DC : 0 BS EN 50441-1 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
04/30117162 DC : DRAFT JUL 2004 EN 50441-3 - SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 3: GRADE 3
BS EN 50441-2:2012 Cables for indoor residential telecommunication installations Screened cables. Grade 1
15/30332386 DC : 0 BS EN 50117-9-3 - COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ
BS EN 50290-2-37:2016 Communication cables Common design rules and construction. Polyethylene insulation for coaxial cables
UNE-EN 50288-10-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
PREN 50441-5 : DRAFT 2017 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 5: CABLES UP TO 2200 MHZ FOR ONE PAIR AND REMAINING PAIRS UP TO 1000 MHZ
I.S. EN 50288-9-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
04/30117156 DC : DRAFT JUL 2004 EN 50441-1 - UN-SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: GRADE 1
BS EN 50117-1 : 2002 COAXIAL CABLES - PART 1: GENERIC SPECIFICATION
PREN 50117-11-2 : DRAFT 2015 COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ
BS EN 50117-4-1 : 2008 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
I.S. EN 50441-2:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
I.S. EN 50290-2-38:2016 COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION FOR COAXIAL CABLES
PREN 50290-2-38 : DRAFT 2013 COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
BS EN 50117-2-3 : 2004 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
I.S. EN 50441-3:2006 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 3: SCREENED CABLES - GRADE 3
BS EN 50173-1:2011 Information technology. Generic cabling systems General requirements
I.S. EN 50288-10-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL FLOOR AND BUILDING BACKBONE CABLES
UNE-EN 50288-8:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz
UNE-EN 50290-2-38:2016 Communication cables - Part 2-38: Common design rules and construction - Polypropylene insulation for coaxial cables
CEI EN 50441-1 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
EN 50173-1:2011 Information technology - Generic cabling systems - Part 1: General requirements
PREN 50441-1 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
EN 50117-1 : 2002 AMD 2 2013 COAXIAL CABLES - PART 1: GENERIC SPECIFICATION
13/30260675 DC : 0 BS EN 50288-10-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
PREN 50117-10-1 : DRAFT 2015 COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
15/30332396 DC : 0 BS EN 50117-11-1 - COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
PREN 50117-10-2 : DRAFT 2015 COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
13/30268920 DC : 0 BS EN 50290-4-2 ED.2 PREN 50290-4-2 ED.2 - COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
13/30277706 DC : 0 BS EN 50288-11-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
13/30260672 DC : 0 BS EN 50288-9-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
BS EN 50117-2-5 : 2004 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MZ
PREN 50117-9-3 : DRAFT 2015 COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ
BS EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized up to 500 MHz. Horizontal floor and building backbone cables
I.S. EN 50117-2-4:2004/A2:2013 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
UTEC 93 531-15 : 2008 INDOOR COMMUNICATION SCREENED CABLE - SCREENED CABLES FOR INDOOR COMMUNICATIONS - RADIOFREQUENCY TELEVISION APPLICATIONS INCLUDING SATELLITE INTERMEDIATE BAND
I.S. EN 50288-11-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-1: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERISED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
I.S. EN 50290-2-37:2016 COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
BS EN 50117-2-2 : 2004 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
I.S. EN 50117-4-1:2008 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
PREN 50290-2-37 : DRAFT 2013 COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
PREN 50288-10-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
CEI EN 50441-4 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
I.S. EN 50117-2-5:2004 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
I.S. EN 50290-4-2:2014 COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
I.S. EN 50117-2-2:2004 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
UNE-EN 50290-4-2:2016 Communication cables - Part 4-2: General considerations for the use of cables - Guide to use
I.S. EN 50173-1:2011 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS
PREN 50117-11-1 : DRAFT 2015 COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
PREN 50117-9-1 : DRAFT 2015 COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
10/30216188 DC : 0 BS EN 50288-9-1 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50117-4-2:2015 Coaxial cables Sectional specification for CATV cables up to 6 GHz used in cabled distribution networks
BS EN 50117-2-4 : 2004 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MZ
BS EN 50441-1:2012 Cables for indoor residential telecommunication installations Unscreened cables. Grade 1
UNE-EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
15/30332377 DC : 0 BS EN 50117-9-2 - COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
13/30293745 DC : 0 BS EN 50290-2-38 - COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
PREN 50117-4-2 : DRAFT 2014 COAXIAL CABLES - PART 4-2: SECTIONAL SPECIFICATION FOR CATV CABLES UP TO 6 GHZ USED IN CABLES DISTRIBUTION NETWORKS
PREN 50117-9-2 : DRAFT 2015 COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
UNE-EN 50290-2-37:2016 Communication cables - Part 2-37: Common design rules and construction - Polyethylene insulation for coaxial cables
UNE-EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
UNE-EN 50288-9-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
I.S. EN 50117-1:2002 COAXIAL CABLES - PART 1: GENERIC SPECIFICATION
EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
EN 50117-2-3:2004/A2:2013 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
EN 50290-4-2:2014 Communication cables - Part 4-2: General considerations for the use of cables - Guide to use
EN 50117-4-2:2015 Coaxial cables - Part 4-2: Sectional specification for CATV cables up to 6 GHz used in cabled distribution networks
EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
EN 50290-2-38:2016 Communication cables - Part 2-38: Common design rules and construction - Polypropylene insulation for coaxial cables
EN 50441-2:2012 Cables for indoor residential telecommunication installations - Part 2: Screened cables - Grade 1
EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz

EN 50289-3-1:2001 Communication cables - Specifications for test methods - Part 3-1: Mechanical test methods - General requirements
EN 50290-1-2:2004 Communication cables - Part 1-2: Definitions

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.