EN 50306-3:2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
31-10-2002
01-07-2008
Introduction
1 Scope
2 Normative references
3 Single and multicore cables
4 Tests
Annex A (informative) Guidance on selection of cables
for type approval
Annex B (informative) Bibliography
Tables
EN 50306-3 specifies requirements for, and constructions and dimensions of, multicore cables, rated 300 V to earth, of the following type:Screened (0,5 mm2 to 2,5 mm2, number of cores from 1 to 4)All cables have stranded tinned copper conductors, and thin wall thickness, halogen-free, insulation and sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at temperatures of 90 °C or 105 °C dependent upon the sheath system type.NOTE 1 For cables with type S2 sheath a temperature of 105 °C is only allowed when specifically tested for the higher rating (i.e. by long-term thermal endurance testing to demonstrate a lifetime of at least 20 000 h at 125 °C).The maximum temperature for short-circuit conditions is 160 °C based on a duration of 5 s.Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-1 1).NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1.NOTE 3 EN 45545-1 is still under development and should be consulted.EN 50306-3 should be used in conjunction with EN 50306-1, General Requirements, and EN 50306 2, Single core cables.
| Committee |
CLC/TC 20
|
| DevelopmentNote |
To be used in conjunction with EN 50306-1. (01/2003)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| NF EN 50306-3 : 2003 | Identical |
| NBN EN 50306-3 : 2003 | Identical |
| NEN EN 50306-3 : 2002 | Identical |
| I.S. EN 50306-3:2002 | Identical |
| PN EN 50306-3 : 2003 | Identical |
| VDE 0260-306-3 : 2003 | Identical |
| DIN EN 50306-3 : 2003 | Identical |
| BS EN 50306-3:2002 | Identical |
| CEI EN 50306-3 : 2003 | Identical |
| UNE-EN 50306-3:2002 | Identical |