• Shopping Cart
    There are no items in your cart

EN 50341-2-22:2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Overhead electrical lines exceeding AC 1 kV - Part 2-22: National Normative Aspects (NNA) for Poland (based on EN 50341-1:2012)

Published date

11-03-2016

Superseded date

07-04-2022

Superseded by

EN 50341-2-22:2022

Sorry this product is not available in your region.
Summarise this standard

European foreword
1 Scope
2 Normative references, definitions and symbols
3 Basis of design
4 Action on lines
5 Electrical requirements
6 Earthing systems
7 Supports
8 Foundations
9 Conductors and earth-wires
10 Insulators
11 Hardware
12 Quality assurance, checks and taking-over
Annex G (normative) - Calculation methods for
        earthing systems
Annex H (informative) - Installation and measurements
        of earthing systems
Annex J (normative) - Angles in lattice steel towers
Annex K (normative) - Steel poles
Annex M (informative) - Geotechnical and structural
        design of foundations

This NNA determines the requirements which shall be fulfilled while designing and constructing of new overhead lines with nominal system voltages exceeding 1 kV AC. The scope of use of this NNA for temporary lines shall be determined by the Project Specification. For modernisations, reconstructions and refurbishments of the existing lines, the scope and the requirement to comply with PN-EN-50341-1, together with this NNA, shall be determined by the Project Specification. 1.2 Field of application (ncpt) PL.1 Overhead lines with covered conductors This NNA applies to overhead lines with covered conductors and overhead insulated cable system with nominal voltage exceeding 1 kV up to 45 kV AC. Additional requirements and simplifications, which apply only to this range of voltages, have been determined. This NNA does not contain requirements applicable for designing and constructing overhead lines with nominal voltage exceeding 45 kV AC, with covered conductors, where internal and external clearances can be smaller than specified in the NNA. (ncpt) PL.2 Optical conductors/wires This NNA also applies to optical phase conductors (OPCON) and optical ground wires (OPGW), containing optical fibre telecommunication circuits, installed on overhead line supports. (ncpt) PL.3 All Dielectric Self Supporting (ADSS) cablesThis NNA applies to all dielectric cables (ADSS) only within the scope of their influence on the load of the support and the requirements of the insulator clearances. (ncpt) PL.4 Installation of telecommunication fittings The NNA also applies to the installation of telecommunication equipment mounted on the new line structures with their primary function as of overhead line supports.

Committee
CLC/TC 11
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Sorry this product is not available in your region.