    Product standard to demonstrate the compliance of wireless communication devices, with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 300 MHz to 6 GHz: devices used next to the ear

    Available format(s): 

    Language(s): 

    Published date:  06-10-2017

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Exposure conditions
    5 Normative limits
    6 Evaluation of compliance
    7 Assessment uncertainty
    8 Documentation
    9 Assessment of compliance
    Annex ZZ (informative) - Relationship between this
             European Standard and the essential
             requirements of Directive 2014/53/EU
             [2014 OJ L153] aimed to be covered
    Bibliography

    Abstract - (Show below) - (Hide below)

    This product standard applies to wireless communication devices used in close proximity to the human ear (e.g. mobile phones, wireless headsets). The applicable frequency range is from 300 MHz to 6 GHz.The objective of this standard is to demonstrate the compliance of such devices with the basic restrictions and exposure limit values related to human exposure to radio frequency electromagnetic fields.For devices used next to the body or in front of the face the applicable product standard is EN 50566:2017.For low power devices the applicable product standard is EN 50663:2017.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 106X
    Development Note Supersedes PREN 50360. (10/2017)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CEI EN 62368-1 : 2016 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
    EN 300 175-2 : 2.6.1 DIGITAL ENHANCED CORDLESS TELECOMMUNICATIONS (DECT); COMMON INTERFACE (CI); PART 2: PHYSICAL LAYER (PHL)
    I.S. EN 50566:2017 PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF WIRELESS COMMUNICATION DEVICES WITH THE BASIC RESTRICTIONS AND EXPOSURE LIMIT VALUES RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE FROM 30 MHZ TO 6 GHZ: HAND-HELD AND BODY MOUNTED DEVICES IN CLOSE PROXIMITY TO THE HUMAN BODY
    BS EN 50566:2017 Product standard to demonstrate the compliance of wireless communication devices with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 30 MHz to 6 GHz: hand-held and body mounted devices in close proximity to the human body
    11/30252989 DC : 0 BS EN 50566 - PRODUCT STANDARD TO DEMONSTRATE COMPLIANCE OF RADIO FREQUENCY FIELDS FROM HANDHELD AND BODY-MOUNTED WIRELESS COMMUNICATION DEVICES (30 MHZ - 6 GHZ)
    01/208272 DC : DRAFT NOV 2001 EN 50CCC-1 - GENERIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF ELECTRONIC AND ELECTRICAL APPARATUS WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
    CEI EN 50566 : 2014 PRODUCT STANDARD TO DEMONSTRATE COMPLIANCE OF RADIO FREQUENCY FIELDS FROM HANDHELD AND BODY-MOUNTED WIRELESS COMMUNICATION DEVICES USED BY THE GENERAL PUBLIC (30 MHZ - 6 GHZ)
    PREN 50566 : DRAFT 2017 PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF WIRELESS COMMUNICATION DEVICES WITH THE BASIC RESTRICTIONS AND EXPOSURE LIMIT VALUES RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE FROM 30 MHZ TO 6 GHZ: HAND-HELD AND BODY MOUNTED DEVICES IN CLOSE PROXIMITY TO THE HUMAN BODY
    TR 102 937 : 1.1.1 ECALL COMMUNICATIONS EQUIPMENT; CONFORMANCE TO EU VEHICLE REGULATIONS, R&TTE, EMC & LV DIRECTIVES, AND EU REGULATIONS FOR ECALL IMPLEMENTATION
    IEEE 1909.1-2014 IEEE Recommended Practice for Smart Grid Communications Equipment -- Test Methods and Installation Requirements
    17/30353676 DC : 0 BS EN 50566 - PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF WIRELESS COMMUNICATION DEVICES WITH THE BASIC RESTRICTIONS AND EXPOSURE LIMIT VALUES RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE FROM 30 MHZ TO 6 GHZ: HAND-HELD AND BODY MOUNTED DEVICES IN CLOSE PROXIMITY TO THE HUMAN BODY
    I.S. EN 62368-1:2014 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED)
    EN 62368-1:2014/AC:2017-03 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED)
    UNE-EN 50566:2013 Product standard to demonstrate compliance of radio frequency fields from handheld and body-mounted wireless communication devices used by the general public (30 MHz - 6 GHz)
    EN 50566:2017 Product standard to demonstrate the compliance of wireless communication devices with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 30 MHz to 6 GHz: hand-held and body mounted devices in close proximity to the human body

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
    EN 50566:2017 Product standard to demonstrate the compliance of wireless communication devices with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 30 MHz to 6 GHz: hand-held and body mounted devices in close proximity to the human body
    EN 50663:2017 Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
    EN 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective