Connector sets and Interconnect components to be used in optical fibre communication systems - Product specifications - Part 17-2: Type FPFT (factory polished field terminated) simplex connector factory terminated with EN 60793-2-50 category B1.3 fibre and field mounted onto reinforced cable containing IEC 60793-2-50 category B1.3 or B6a1 or B6a 2 singlemode fibre (with restricted MFD), category C

Published date

16-01-2015

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Description
4 Variants
5 Dimensional requirements - Ferrule
  end face geometry after termination
6 Tests
7 Test report
8 Testing requirements
Annex A (normative) - Sample size and product
        sourcing requirements
Annex B (informative) - Reference connector details
Bibliography

1.1Product definitionThis European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that a Factory Polished Field Terminated (FPFT) single mode simplex connector set (plug adaptor plug) will meet in order for it to be categorized as an EN standard product.The FPFT is designed for either fusion or mechanical splice methods. The performance is specified for the mated combination between a FPFT plug and an EN standardized plug from the EN 50377 series (configuration 1) or between two FTFP plugs (configuration 2). The fibre specified inside the FPFT plug in this European Standard is standard single mode fibre with low water peak as specified as B1.3, which is field mated to B1.3 fibre or bend insensitive single mode fibre specified as B6_a1 or B6_a2 in EN 60793 2 50. Mixing standard and bend insensitive fibres in a connection potentially causes a considerable intrinsic attenuation due to mode field diameter mismatch. These connectors are intended to be for an indoor installation. The connectors are terminated onto reinforced cables according to EN 60794 2 50 with outer diameter greater than 0,9 and up to 3 mm.Since different variants and grades of performance are permitted, product marking details are given in 3.6.1.2Intermateability1.2.1Mechanical intermateabilityIn order to meet mechanical performance requirements, the FPFT plug will meet the optical, environmental and mechanical requirements as stated in this European Standard and the mated plug will meet all the requirements of the relevant EN 50377 series for category C. Intermateability between the FPFT plug and its standard EN 50377 counterpart can only be guaranteed when both plugs meet the same EN 50377 product specification mechanical connector interface dimensions and end face geometry requirements.1.2.2Optical intermateabilityIn EN 50377 product specifications, the random mated performance is calculated when the two connector plugs have been terminated with single-mode fibres using a worst case MFD. The specified MFD range in fibre standards (e.g. B1.3 fibres) is 8,0 μm to 10,1 μm at 1 310 nm, which causes 0,22 dB worst case intrinsic attenuation. However, in EN 50377 product specification series, the MFD is limited to 8,9 μm to 9,5 μm at 1 310 nm. In this European Standard, in order to achieve the random mate performance values, the total MFD range of bend insensitive fibres, e.g. B6a fibres, is limited to 8,5 μm to 9,5 μm at 1 310 nm. This causes a worst case intrinsic attenuation of 0,05 dB.1.3Operating environmentThe tests selected, combined with the severities and durations, are representative of a category C environment as defined in EN 61753 1. The FPFT plugs are terminated to reinforced optical cables with outer diameter greater than 0,9 mm and up to 3 mm.1.4ReliabilityWhile the anticipated service life expectancy of the product in this environment is 20 years, compliance with this European Standard does not guarantee the reliability of the product. This should be predicted using a recognized reliability assessment programme.1.5Quality assuranceCompliance with this European Standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recognized quality assurance programme.

Committee
CLC/TC 86BXA
DevelopmentNote
Supersedes PREN 50377-17-2. (01/2015)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

EN 61300-2-5:2011 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
EN 61300-2-18:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance
IEC 61300-3-28:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss
EN 61300-2-1:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)
EN 61300-3-4:2013 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation
EN 60794-2:2017 Optical fibre cables - Part 2: Indoor cables - Sectional specification
IEC 61300-3-16:2003 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of spherically polished ferrules
EN 61300-2-17:2011 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold
EN 60793-2-50:2016 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres
EN 61300-2-2:2009/corrigendum:2009 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-2: TESTS - MATING DURABILITY
IEC 61300-2-1:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)
IEC 61300-2-12:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact
PREN 50411-3-5 : DRAFT 2013 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-5 WALL OUTLET
EN 61300-2-22:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature
IEC 61300-2-17:2010 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold
IEC 61753-1:2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards
EN 61753-1:2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards
EN 61300-3-23:1998 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examination and measurements - Fibre position relative to ferrule endface
IEC 61300-2-5:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
IEC 61300-3-34:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors
IEC 61300-3-23:1998 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examination and measurements - Fibre position relative to ferrule endface
EN 61300-3-16:2003 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of spherically polished ferrules
EN 61300-1:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance
IEC 61300-2-18:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance
IEC 61300-2-22:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature
EN 60794-2-50 : 2008 OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
IEC 61300-1:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance
IEC 61300-3-6:2008 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss
IEC 61300-3-15:2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-15: Examinations and measurements - Dome eccentricity of a convex polished ferrule endface
EN 61300-3-6:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss
EN 61300-2-12:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact
IEC 61300-3-4:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation
EN 61300-2-4:1997 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
EN 61300-3-15:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-15: Examinations and measurements - Dome eccentricity of a convex polished ferrule endface
EN 61300-3-28:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss
IEC 60793-2-50:2015 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres
IEC 60794-2:2017 Optical fibre cables - Part 2: Indoor cables - Sectional specification
IEC 61300-2-2:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests - Mating durability
IEC 61300-2-4:1995 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
IEC 61300-2-19:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
EN 61300-2-19:2013 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
EN 61300-3-34:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors
IEC 60794-2-50:2008 Optical fibre cables - Part 2-50: Indoor cables - Family specification for simplex and duplex cables for use in terminated cable assemblies

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.