1 Scope
2 Normative references
3 Terminology and abbreviations
3.1 Terminology
3.2 Abbreviations
4 General information
4.1 General cable description
4.2 Environment and product safety requirement
4.3 Testing
5 Requirements for conductor
5.1 Construction and dimensions
5.2 Mechanical requirements
5.3 Electrical requirements
5.3.1 Conductor resistance
5.3.2 Conductor resistance unbalance
6 Requirements for insulation
6.1 Construction material and dimensions
6.1.1 Construction
6.1.2 Colour code
6.2 Mechanical requirements
6.3 Electrical requirements
6.3.1 Insulation resistance
6.3.2 Dielectric strength
7 Requirements for cable element
7.1 Construction and dimensions
7.1.1 Screening of the cable element
7.1.2 Spare cable elements
8 Requirements for cable core
8.1 Design
8.1.1 General
8.1.2 Screen
8.1.3 Interstitial fillers
9 Requirements for filling compounds
10 Requirements for the screening of the cable core
11 Requirement for the armour
12 Requirements for the sheath
12.1 Colour of sheath
12.2 Mechanical requirements of the sheath
13 Cable identification
14 Requirements for finished cable
14.1 Mechanical requirements
14.1.1 Bending
14.1.2 Impact
14.1.3 Tensile (under consideration)
14.1.4 Crush resistance
14.2 Environmental requirements
14.2.1 Temperature range
14.2.2 Cold bend
14.2.3 Fauna and mould proofing
14.2.4 Moisture barriers
15 Electrical requirements
15.1 Dielectric strength
15.2 Mutual capacitance
15.3 Capacitance unbalance
15.4 Velocity of propagation
15.5 Attenuation
15.6 Longitudinal Conversion Loss (LCL)
15.7 Near End Crosstalk (NEXT)
15.8 Equal Level Far-End Crosstalk loss (ELFEXT)
15.9 Power Sum (PS) of crosstalk losses
15.10 Characteristic impedance
15.11 Coupling attenuation
15.12 Transfer impedance
16 Product qualification requirements
This European Standard defines outdoor multi-pair cables for use in high bit rate digital telecommunication networks with their relative definitions and requirements.It covers water tight cables, with an overall screen, for applications up to 10 MHz, to be used in outdoor networks (for example in the subscriber access loop).The electrical, mechanical, transmission performance characteristics of the screened cables, related to their reference test methods, are detailed.
Committee |
CLC/TC 46X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
SN EN 50407-1 : 2004 | Identical |
DIN EN 50407-1:2005-02 | Identical |
UNE-EN 50407-1:2004 | Identical |
BS EN 50407-1:2004 | Identical |
NBN EN 50407-1 : 2005 | Identical |
CEI EN 50407-1 : 2006 | Identical |
NF EN 50407-1 : 2004 | Identical |
PN EN 50407-1 : 2005 | Identical |
I.S. EN 50407-1:2004 | Identical |
NEN EN 50407-1 : 2004 | Identical |
PNE-prEN 50407-1 | Identical |
PREN 50290-4-2 : DRAFT 2013 | COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE |
I.S. EN 50290-2-23:2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
UNE-EN 50290-2-23:2014 | Communication cables - Part 2-23: Common design rules and construction - Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables |
BS EN 50290-2-23:2013 | Communication cables Common design rules and construction. Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables |
TS 102 872 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); COPPER EXTERNAL NETWORK TESTING INTERFACE |
CEI EN 50290-2-23 : 2014 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
13/30268920 DC : 0 | BS EN 50290-4-2 ED.2 PREN 50290-4-2 ED.2 - COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE |
13/30281393 DC : 0 | BS EN 50290-2-23 - COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION |
07/30154013 DC : 0 | EN 50290-2-4 - COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE FOR USE |
PREN 50290-2-23 : DRAFT 2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION |
EN 50290-2-23:2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
IEC 60028:1925 | International standard of resistance for copper |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
HD 402 : 200S2 | STANDARD COLOURS FOR INSULATION FOR LOW-FREQUENCY CABLES AND WIRES |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
EN 60811-1-1:1995/A1:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.