• EN 50470-3:2006

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electricity metering equipment (a.c.) - Part 3: Particular requirements - Static meters for active energy (class indexes A, B and C)

    Available format(s): 

    Superseded date:  25-11-2019

    Language(s): 

    Published date:  27-10-2006

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Standard electrical values
    5 Mechanical requirements
    6 Climatic conditions
    7 Electrical requirements
       7.1 Power consumption
            7.1.1 Measurement method
            7.1.2 Voltage circuits
            7.1.3 Current circuits
       7.2 AC voltage test
    8 Accuracy requirements and tests
       8.1 Limits of percentage error due to variation of the load
       8.2 Repeatability
       8.3 Limits of additional percentage error due to influence
            quantities
       8.4 Maximum permissible error (MPE)
       8.5 Effect of disturbances of long duration
       8.6 Short time overcurrents
       8.7 Performing the tests
            8.7.1 Accuracy test conditions
            8.7.2 Accuracy tests at reference conditions
            8.7.3 Interpretation of accuracy test results
            8.7.4 Repeatability
            8.7.5 Test of effects of influence quantities
            8.7.6 Calculation of the composite error
            8.7.7 Test of effects of disturbances of long duration
            8.7.8 Short time overcurrents
            8.7.9 Test of starting and no-load condition
            8.7.10 Meter constant
    9 Durability
    10 Reliability
    11 Requirements concerning the software and protection against
       corruption
       11.1 General
       11.2 Identification of functions implemented in software
       11.3 Identification and protection of software
       11.4 Identification and protection of metrologically
            relevant parameters
       11.5 Setting of parameters
       11.6 Protection of measurement data
       11.7 Protection against inadmissible influence by
            metrologically non-relevant software
       11.8 Protection against inadmissible influence by connecting
            another device
    Annex A (informative) Calculation of the composite error
    Annex B (normative) Test circuit diagram for the test of
            immunity to earth fault
    Annex C (normative) Test circuit diagram for d.c., even
            harmonics, odd harmonics and sub-harmonics
    Annex ZZ (informative) Coverage of Essential Requirements of
             EC Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard applies to newly manufactured static watt-hour meters intended for residential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and type test methods. It applies to static watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this standard applies only for the active energy metering part. This standard distinguishes between: –meters of class indexes A, B and C; –direct connected and transformer operated meters; –meters for use in networks equipped with or without earth fault neutralizers. It does not apply to: –watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); –portable meters; –reference meters. Methods for acceptance testing are covered by the IEC 62058 series of standards. The dependability aspect is covered by the documents of the IEC 62059 series.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 13
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 50470-1:2006 Electricity metering equipment (a.c.) - Part 1: General requirements, tests and test conditions - Metering equipment (class indexes A, B and C)
    IEC 61851-1:2017 Electric vehicle conductive charging system - Part 1: General requirements
    PD CLC/TR 50579:2012 Electricity metering equipment (A.C.). Severity levels, immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz-150 kHz
    S.R. CLC/TR 50579:2012 ELECTRICITY METERING EQUIPMENT (A.C.) - SEVERITY LEVELS, IMMUNITY REQUIREMENTS AND TEST METHODS FOR CONDUCTED DISTURBANCES IN THE FREQUENCY RANGE 2 KHZ - 150 KHZ
    UNE-EN 62058-31:2011 Electricity metering equipment (a.c.) - Acceptance inspection -- Part 31: Particular requirements for static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2, and class indexes A, B and C)
    I.S. EN 62058-31:2010 ELECTRICITY METERING EQUIPMENT (A.C.) - ACCEPTANCE INSPECTION - PART 31: PARTICULAR REQUIREMENTS FOR STATIC METERS FOR ACTIVE ENERGY (CLASSES 0,2 S, 0,5 S, 1 AND 2, AND CLASS INDEXES A, B AND C)
    I.S. EN 50470-1:2006 ELECTRICITY METERING EQUIPMENT (A.C.) - PART 1: GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - METERING EQUIPMENT (CLASS INDEXES A, B AND C)
    S.R. CLC/TR 50627:2015 STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ
    CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
    BS EN 62058-31:2010 ELECTRICITY METERING EQUIPMENT (A.C.) - ACCEPTANCE INSPECTION - PART 31: PARTICULAR REQUIREMENTS FOR STATIC METERS FOR ACTIVE ENERGY (CLASSES 0,2 S, 0,5 S, 1 AND 2, AND CLASS INDEXES A, B AND C)
    PD CLC/TR 50627:2015 STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ
    CLC/TR 50579:2012 ELECTRICITY METERING EQUIPMENT (A.C.) - SEVERITY LEVELS, IMMUNITY REQUIREMENTS AND TEST METHODS FOR CONDUCTED DISTURBANCES IN THE FREQUENCY RANGE 2 KHZ - 150 KHZ
    CEI CLC/TR 50579 : 2013 ELECTRICITY METERING EQUIPMENT - SEVERITY LEVELS, IMMUNITY REQUIREMENTS AND TEST METHODS FOR CONDUCTED DISTURBANCES IN THE FREQUENCY RANGE 2 KHZ - 150 KHZ
    CEI EN 50470-1 : 2007 ELECTRICITY METERING EQUIPMENT (A.C.) - PART 1: GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - METERING EQUIPMENT (CLASS INDEXES A, B AND C)
    BS EN 50470-1 : 2006 ELECTRICITY METERING EQUIPMENT (A.C.) - PART 1: GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - METERING EQUIPMENT (CLASS INDEXES A, B AND C)
    15/30269927 DC : 0 BS EN 61851-1 ED 3.0 - ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM PART 1: GENERAL REQUIREMENTS
    CEI EN 62058-31 : 2012 ELECTRICITY METERING EQUIPMENT (A.C.) - ACCEPTANCE INSPECTION - PART 31: PARTICULAR REQUIREMENTS FOR STATIC METERS FOR ACTIVE ENERGY (CLASSES 0,2 S, 0,5 S, 1 AND 2, AND CLASS INDEXES A, B AND C)
    EN 62058-31:2010 Electricity metering equipment (a.c.) - Acceptance inspection - Part 31: Particular requirements for static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2, and class indexes A, B and C)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62053-21:2003+AMD1:2016 CSV Electricity metering equipment (a.c.) - Particular requirements - Part 21: Static meters for active energy (classes 1 and 2)
    IEC TR 60736:1982 Testing equipment for electrical energy meters
    2004/22/EC : 2004 DIRECTIVE 2004/22/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 31 MARCH 2004 ON MEASURING INSTRUMENTS
    EN 62059-41:2006 Electricity metering equipment - Dependability - Part 41: Reliability prediction
    IEC 62059-41:2006 Electricity metering equipment - Dependability - Part 41: Reliability prediction
    IEC TR 62059-21:2002 Electricity metering equipment - Dependability - Part 21: Collection of meter dependability data from the field
    IEC 62053-61:1998 Electricity metering equipment (a.c.) - Particular requirements - Part 61: Power consumption and voltage requirements
    EN 50470-1:2006 Electricity metering equipment (a.c.) - Part 1: General requirements, tests and test conditions - Metering equipment (class indexes A, B and C)
    IEC 62058-31:2008 Electricity metering equipment (AC) - Acceptance inspection - Part 31: Particular requirements for static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2)
    EN 62053-61:1998 Electricity metering equipment (a.c.) - Particular requirements - Part 61: Power consumption and voltage requirements
    IEC 62053-22:2003+AMD1:2016 CSV Electricity metering equipment (a.c.) - Particular Requirements - Part 22: Static meters for active energy (classes 0,2 S and 0,5 S)
    IEC 62058-11:2008 Electricity metering equipment (AC) - Acceptance inspection - Part 11: General acceptance inspection methods
    IEC TR 62059-11:2002 Electricity metering equipment - Dependability - Part 11: General concepts
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective