• There are no items in your cart

EN 50522:2022

Current

Current

The latest, up-to-date edition.

Earthing of power installations exceeding 1 kV a.c.

Published date

04-03-2022

Sorry this product is not available in your region.

This document is applicable to specify the requirements for the design and erection of earthing systems of electrical installations, in systems with nominal voltage above 1 kV AC and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended.NOTE 1 The technical and procedural principles of this document can be applied when 3rd parties’ installations and facilities are planned and/or erected in the vicinity of HV electrical power installations.For the purpose of interpreting this document, an electrical power installation is considered to be one of the following:a)substation, including substation for railway power supply;b)electrical power installations on mast, pole and tower;switchgear and/or transformers located outside a closed electrical operating area;c)one (or more) power station(s) located on a single site;the electrical power installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded;d)the electrical system of a factory, industrial plant or other industrial, agricultural, commercial or public premises;e)electrical power installations on offshore facilities for the purpose of generation, transmission, distribution and/or storage of electricity;f)transition towers/poles between overhead lines and underground lines.The electrical power installation includes, among others, the following equipment:—rotating electrical machines;—switchgear;—transformers and reactors;—converters;—cables;—wiring systems;—batteries;—capacitors;—earthing systems;—buildings and fences which are part of a closed electrical operating area;—associated protection, control and auxiliary systems;—large air core reactor.NOTE 2In general, a standard for an item of equipment takes precedence over this document.This document does not apply to the design and erection of earthing systems of any of the following:—overhead and underground lines between separate installations;NOTE 3The standard, EN 50341 series Overhead lines exceeding AC 1 kV, specifies requirements for the design and erection of earthing systems in overhead lines.—electrified railway tracks and rolling stock;—mining equipment and installations;—fluorescent lamp installations;—installations on ships and off-shore installations;—electrostatic equipment (e.g. electrostatic precipitators, spray-painting units);—test sites;—medical equipment, e.g. medical X-ray equipment.NOTE 4 The scope of this document does not include the requirements for carrying out live working on electrical power installations.NOTE 5 The scope of this document considers safety requirements for HV installations and its influences on LV installations. For electrical installation up to 1 kV, the standard IEC 60364 series applies.

Committee
CLC/TC 99X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Standards Relationship
CEI EN 50522:2022 Identical
PN-EN 50522:2022-12 Identical
I.S. EN 50522:2022 Identical
DS/EN 50522:2022 Identical
OVE EN 50522:2023 11 01 Identical
VDE 0101-2:2023-10 Identical
DIN EN 50522:2023-10 Identical
UNE-EN 50522:2022 Identical
BS EN 50522:2022 Equivalent

DS/EN 50341-2-21:2023 Overhead electrical lines exceeding AC 1 kV – National Normative Aspects (NNA) for Slovenia (based on EN 50341-1:2012)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.