EN 50525-1:2011

Current

Current

The latest, up-to-date edition.

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements

Published date

06-05-2011

Sorry this product is not available in your region.
Summarise this standard

Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Requirements for the construction of cables
6 Marking
7 Tests on completed cables
8 Guide to use of the cables
Annex A (normative) - Mechanical tests - Requirements
        for flexible cables
Annex B (normative) - Assessment of halogens
Annex C (normative) - Determination of halogens -
        Elemental test
Annex D (normative) - Requirements for core
        identification of multicore cables with more
        than five cores
Annex E (informative) - Structure and content of
        EN 50525 and its derivation from HD 21 and
        HD 22
Bibliography

This European Standard gives the general requirements for rigid and flexible energy cables of rated voltages U0/U up to and including 450/750 V a.c., used in power installations and with domestic and industrial appliances and equipment. NOTE 1For some types of flexible cables, the term "cord" is used. NOTE 2Rated voltages are given by reference to alternating current (a.c.) systems. Use of the cables in direct current (d.c.) systems is permitted. NOTE 3National regulations may prescribe additional performance requirements for cables that are not given in the particular requirements. For example for buildings with high levels of public access, additional fire performance requirements may be applicable, The test methods for checking conformity with the requirements are given in other standards (see Introduction). The particular types of cables are specified in EN 50525-2 (series) and EN 50525-3 (series). The individual parts within those two series are collectively referred to hereafter as "the particular specifications". Only the sizes (conductor class, cross-sectional area), number of cores, other constructional features and rated voltages given in the particular specification apply to the individual cable type. The code designations of these types of cables are in accordance with HD 361.

Committee
CLC/TC 20
DevelopmentNote
Supersedes HD 21.1 and HD 22-1. (05/2011) Supersedes PREN 50525-1. (08/2011)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Sorry this product is not available in your region.