• EN 50527-1:2016

    Current The latest, up-to-date edition.

    Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 1: General

    Available format(s): 

    Language(s): 

    Published date:  02-12-2016

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Risk assessment
    5 Equipment at workplaces
    6 Special cases
    7 AIMD-Employees with more than one AIMD
    8 Documentation
    Annex A (normative) - Specific risk assessment
    Annex B (informative) - Documenting the risk assessment
    Annex C (informative) - Specific electromagnetic environments
    Annex D (informative) - Theoretical considerations
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard provides a procedure to assess the risk to workers bearing one or more active implantable medical devices from exposure to electric, magnetic and electromagnetic fields at a workplace. It describes how a general risk assessment should be performed and determines whether it is necessary to carry out a detailed risk assessment.NOTE 1This European Standard does not cover indirect effects caused by non active implants.NOTE 2The risk of human exposure to EMF considered is only due to malfunctioning of AIMD. Possibilities of AIMD contribution to the risk, e.g. local modification of the distribution of EMF produced by external source or production of own EMF, are covered by the respective product standards for the AIMD.Based on specific workplace standards it can be determined whether preventive measures/actions need to be taken to comply with the provisions of Directive 2013/35/EU. The work situation covered is considered to be under normal working conditions including normal operation, maintenance, cleaning and other situations being part of the normal work.The frequencies covered are from 0 Hz to 300 GHz.The European Parliament and Council Directive 2013/35/EU will be transposed into national legislation in all the EU member countries. It is recommended that users of this standard consult the national legislation related to this transposition in order to identify the national regulations and requirements. These national regulations and requirements may have additional requirements that are not covered by this standard and take precedence.NOTE 3Performance requirements with respect to active implantable medical devices are excluded from the Scope of this standard. These are defined in the relevant particular standards for active implantable medical devices.The risk assessment described in this standard is only required if an AIMD-Employee is present.Active Implantable Medical Devices (AIMDs) are regulated by Directive 90/385/EEC and the amendments to it.NOTE 4Product standards EN 45502-1 and of the EN 45502-2-X series describe the product requirements for different kinds of AIMDs. Different kinds of AIMDs are e.g. pacemaker (EN 45502-2-1), implantable cardioverter defibrillators (EN 45502-2-2), cochlear implants (EN 45502-2-3), implantable neurostimulators (ISO 14708-3), implantable infusion pumps (ISO 14708-4).In situations where the risk assessment following this standard does not lead to a conclusion, complementary provisions for the assessment of workers exposure for different kinds of AIMDs are given in particular standards for these specific AIMDs (see Figure 1).(...)Figure 1 - Structure of the EN 50527 family of standards

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 106X
    Development Note Supersedes PREN 50527-1. (12/2016)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 50527-2-1:2016 Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-1: Specific assessment for workers with cardiac pacemakers
    17/30359914 DC : 0 BS EN 50527-2-2 - PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIOVERTER DEFIBRILLATORS (ICDS)
    PREN 50499 : DRAFT 2017 PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE OF WORKERS TO ELECTROMAGNETIC FIELDS
    CEI EN 50647 : 1ED 2018 BASIC STANDARD FOR THE EVALUATION OF WORKERS' EXPOSURE TO ELECTRIC AND MAGNETIC FIELDS FROM EQUIPMENT AND INSTALLATIONS FOR THE PRODUCTION, TRANSMISSION AND DISTRIBUTION OF ELECTRICITY
    BS EN 50527-2-1:2016 Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices Specific assessment for workers with cardiac pacemakers
    PREN 50527-2-2 : DRAFT 2017 PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIOVERTER DEFIBRILLATORS (ICDS)
    UNE-EN 50527-2-1:2012 Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-1: Specific assessment for workers with cardiac pacemakers
    EN 50647:2017 Basic standard for the evaluation of workers' exposure to electric and magnetic fields from equipment and installations for the production, transmission and distribution of electricity
    EN 50527-2-2:2018 Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-2: Specific assessment for workers with cardioverter defibrillators (ICDs)
    PREN 50527-2-1 : DRAFT 2015 PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIAC PACEMAKERS
    15/30321270 DC : 0 BS EN 50527-2-1 - PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIAC PACEMAKERS
    I.S. EN 50496:2018 DETERMINATION OF WORKERS' EXPOSURE TO ELECTROMAGNETIC FIELDS AND ASSESSMENT OF RISK AT A BROADCAST SITE
    I.S. EN 50527-2-1:2016 PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIAC PACEMAKERS
    17/30365898 DC : 0 BS EN 50499 - PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE OF WORKERS TO ELECTROMAGNETIC FIELDS
    BS EN 50647:2017 Basic standard for the evaluation of workers\' exposure to electric and magnetic fields from equipment and installations for the production, transmission and distribution of electricity
    I.S. EN 50647:2017 BASIC STANDARD FOR THE EVALUATION OF WORKERS' EXPOSURE TO ELECTRIC AND MAGNETIC FIELDS FROM EQUIPMENT AND INSTALLATIONS FOR THE PRODUCTION, TRANSMISSION AND DISTRIBUTION OF ELECTRICITY
    EN 50496:2018 Determination of workers' exposure to electromagnetic fields and assessment of risk at a broadcast site

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50500 : 2008 AMD 1 2015 MEASUREMENT PROCEDURES OF MAGNETIC FIELD LEVELS GENERATED BY ELECTRONIC AND ELECTRICAL APPARATUS IN THE RAILWAY ENVIRONMENT WITH RESPECT TO HUMAN EXPOSURE
    PREN 50527-2-2 : DRAFT 2017 PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIOVERTER DEFIBRILLATORS (ICDS)
    2007/47/EC : 2007 COR 1 2015 DIRECTIVE 2007/47/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 5 SEPTEMBER 2007 AMENDING COUNCIL DIRECTIVE 1990/385/EEC ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ACTIVE IMPLANTABLE MEDICAL DEVICES, COUNCIL DIRECTIVE 1993/42/EEC CONCERNING MEDICAL DEVICES AND DIRECTIVE 1998/8/EC CONCERNING THE PLACING OF BIOCIDAL PRODUCTS ON THE MARKET(TEXT WITH EEA RELEVANCE)
    EN 45502-2-2 : 2008 COR 2009 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS)
    ISO 14708-3:2017 Implants for surgery — Active implantable medical devices — Part 3: Implantable neurostimulators
    ISO 14708-4:2008 Implants for surgery Active implantable medical devices Part 4: Implantable infusion pumps
    EN 45502-1:2015 IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER
    EN 45502-1 : 2015 IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER
    EN 45502-2-1:2003 Active implantable medical devices - Part 2-1: Particular requirements for active implantable medical devices intended to treat bradyarrhythmia (cardiac pacemakers)
    EN 50413 : 2008 AMD 1 2013 BASIC STANDARD ON MEASUREMENT AND CALCULATION PROCEDURES FOR HUMAN EXPOSURE TO ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
    EN 50499:2008 Procedure for the assessment of the exposure of workers to electromagnetic fields
    EN 45502-2-3:2010 Active implantable medical devices - Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems
    EN 45502-2-2 : 2008 COR 2009 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective