• EN 50539-11:2013

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 11: Requirements and tests for SPDs in photovoltaic applications

    Available format(s): 

    Withdrawn date:  15-10-2015

    Language(s): 

    Published date:  22-03-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Abstract - (Show below) - (Hide below)

    This European Standard defines the requirements and tests for SPDs intended to be installed on the d.c. side of photovoltaic installations to protect against induced and direct lightning effects. These devices are connected to d.c. power circuits of photovoltaic generators, rated up to 1 500 V.It takes into account that photovoltaic generators:•behave like current generators,•that their nominal current depends on the light intensity,•that their short-circuit current is almost equal to the nominal current,•are connected in series and/or parallel combinations leading to a great variety of voltages, currents and powers from a few hundreds of W (in residential installations) to several MW (photovoltaic fields). The very specific electrical parameters of PV installations on the d.c. side require specific test requirements for SPDs. SPDs with separate input and output terminal(s) that contain a specific series impedance between these terminal(s) (so called two port SPDs according to EN 61643-11) are currently not sufficiently covered by the requirements of this standard and require additional consideration.NOTEIn general SPDs for PV applications do not contain a specific series impedance between the input/output terminals due to power efficiency considerations.SPDs complying with this standard are exclusively dedicated to be installed on the d.c. side of photovoltaic generators. PV installation including batteries and other d.c. applications are not taken into account and additional requirements and tests may be necessary for such applications.SPDs for which the manufacturers declares short circuit mode overload behaviour, shall require specific measures to ensure that such devices will not endanger the operator during maintenance and replacement due to possible d.c. arcing.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 37A
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Withdrawn