EN 50588-4:2018
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 4: Transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 2 for use on transformers meeting the requirements of EN 50588-2
25-12-2020
16-03-2018
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 High-voltage connections
5 Low-voltage connections
6 Design
7 Test
Cable boxes described in this European Standard correspond to cable boxes Type 2 in EN 50588-2 and are suitable for assembly on the cover of oil-immersed distribution transformers meeting the requirements of EN 50588-2.Cable boxes are air-filled, metal- or non-metal enclosed, for high- and/or low-voltage connections in the following variations:1.1High-voltage sidea)Connection directly to bushings;b)Connection via busbar system.1.2Low-voltage sidea)Connection directly to bushings (maximum of four connectors per bushing);b)Connection via busbar system.
Committee |
CLC/TC 14
|
DevelopmentNote |
Supersedes EN 50464-2-3. (03/2018)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
DS/EN 50588-4 : 2018 | Identical |
CEI EN 50588-4 : 2018 | Identical |
NF EN 50588-4 : 2018 | Identical |
PN-EN 50588-4 : 2018-08 | Identical |
SS-EN 50588-4 : 2018 | Identical |
SN EN 50588-4 : 2018 | Identical |
OVE EN 50588-4: 2020 01 01 | Identical |
UNE-EN 50588-4:2018 | Identical |
BS EN 50588-4:2018 | Identical |
NEN EN 50588-4 : 2018 | Identical |
EN 50386:2010/A1:2013 | BUSHINGS UP TO 1 KV AND FROM 250 A TO 5 KA, FOR LIQUID FILLED TRANSFORMERS |
EN 50180:2010 | Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.