EN 54-13:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components
28-02-2020
15-02-2017
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Assessment methods and tests
Annex A (informative) - Example of levels used
in FDAS
Annex B (informative) - Classification of functions
of the FDAS
Annex C (informative) - Example methodology for
theoretical analysis
Annex D (normative) - Software design documentation
Annex E (informative) - Flowchart for assessment of
compatibility/connectability
This document specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system. The components comply either with the requirements of EN 54 or with a manufacturer’s specification where there is no EN 54 standard. This document only includes system requirements when these are necessary for compatibility assessment.This document covers transmission path only between components. However ,requirements for TP between components of a function which is distributed are covered by the relevant EN 54 standard and not by this document.This document also specifies requirements for the integrity of the fire detection and fire alarm system when connected to other systems.This document does not specify the manner in which the system is designed, installed and used in any particular application.This document recognizes that it is not practical to assess the compatibility or connectability of components in all possible configurations. Methods of assessment are specified to reach an acceptable degree of confidence within pre-determined operational and environmental conditions.This document specifies requirements related to compatibility and connectability assessment methods and tests for the components belonging to FDAS or connecting FDAS. This document does not cover components or functions which are not included in a FDAS.This document is applicable to systems where the components are interconnected by electrical wires or optical fibre or by radio frequency links or by any combination. For other interconnection technology between components , this standard may be used as a guidance.NOTE Other European Standards are expected to cover the requirements of the other systems to which the fire detection and fire alarm system may be connected.
Committee |
CEN/TC 72
|
DevelopmentNote |
Supersedes PREN 54-13. (02/2017)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
DIN EN 54-13:2017-05 | Identical |
ONORM EN 54-13:2018 | Identical |
UNI EN 54-13:2017 | Identical |
NBN EN 54-13 : 2005 | Identical |
NEN EN 54-13 : 2017 | Identical |
UNE-EN 54-13:2006 | Identical |
PN EN 54-13 : 2017 | Identical |
NS EN 54-13 : 2017 | Identical |
SS-EN 54-13:2017 | Identical |
BS EN 54-13:2017 | Identical |
DIN EN 54-13:2014-09 (Draft) | Identical |
ONORM EN 54-13 : 2017 | Identical |
NF EN 54-13 : 2017 | Identical |
SN EN 54-13 : 2017 | Identical |
I.S. EN 54-13:2017 | Identical |
UNI EN 54-13 : 2005 | Identical |
UNE-EN 54-13:2019 | Identical |
I.S. EN 50600-2-5:2016 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
EN 50600-2-5:2016 | Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems |
04/30119106 DC : DRAFT AUG 2004 | EN 14972 - FIXED FIREFIGHTING SYSTEMS - WATERMIST SYSTEMS - DESIGN AND INSTALLATION |
VDI 6010 Blatt 2:2011-05 | Technical safety installations - Automation and control of fire protective services |
11/30249544 DC : 0 | BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
ISO/IEC TS 22237-6:2018 | Information technology — Data centre facilities and infrastructures — Part 6: Security systems |
BS EN 54-25:2008 | Fire detection and fire alarm systems Components using radio links |
BS EN 14637:2007 | Building hardware. Electrically controlled hold-open systems for fire/smoke door assemblies. Requirements, test methods, application and maintenance |
07/30164493 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATIONS AND MAINTENANCE |
CEI EN 50600-2-5 : 2017 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
BS EN 54-27:2015 | Fire detection and fire alarms systems Duct smoke detectors |
UNI EN 54-25 : 2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
I.S. EN 54-25:2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
EN 14637:2007 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 54-27:2015 | Fire detection and fire alarms systems - Part 27: Duct smoke detectors |
DIN EN 54-27:2015-05 | Fire detection and fire alarm systems - Part 27: Duct smoke detectors |
I.S. EN 54-27:2015 | FIRE DETECTION AND FIRE ALARMS SYSTEMS - PART 27: DUCT SMOKE DETECTORS |
DIN EN 54-25:2015-10 (Draft) | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
DIN EN 14637:2008-01 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 54-16:2008 | Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.