• EN 54-31:2014+A1:2016

    Current The latest, up-to-date edition.

    Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors

    Available format(s): 

    Language(s): 

    Published date:  27-04-2016

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
    5 Testing, assessment and sampling methods
    6 Classification and designation
    7 Marking, Labelling and Packaging
    Annex A (normative) - Smoke tunnel for smoke response
             values
    Annex B (normative) - Test aerosol for smoke response
            value measurements
    Annex C (normative) - Smoke measuring instruments
    Annex D (normative) - Gas test chamber for CO response
             threshold value and crosssensitivity to chemical agents
    Annex E (normative) - Heat tunnel for heat response value
    Annex F (normative) - Measuring instruments for CO
    Annex G (informative) - Establishing exposure levels of
            chemical agents
    Annex H (normative) - Apparatus for dazzling test
    Annex I (informative) - Apparatus for impact test
    Annex J (normative) - Fire test room
    Annex K (normative) - Open wood fire (TF1)
    Annex L (normative) - Smouldering (pyrolysis) wood fire (TF2)
    Annex M (normative) - Glowing smouldering cotton fire (TF3)
    Annex N (normative) - Open plastics (polyurethane) fire (TF4)
    Annex O (normative) - Liquid (heptane) fire (TF5)
    Annex P (normative) - Low temperature black smoke
            (decalene) liquid fire (TF8)
    Annex Q (informative) - Information concerning the
            construction of the smoke tunnel
    Annex R (informative) - Information concerning the
            construction of the gas test chamber
    Annex S (informative) - Construction of the heat tunnel
    Annex T (informative) - Information concerning test
            procedures and requirements for response to slowly
            developing fires, aging and contamination
    Annex U (informative) - Information concerning the
            construction of the measuring ionization chamber
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes of operation, where at least the signals of both smoke and carbon monoxide sensors are continuously evaluated.This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke, carbon monoxide and optionally heat sensors to this EN.Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors, which are having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 72
    Development Note Supersedes PREN 54-31. (12/2014) 2014 Edition Re-Issued in April 2016 & incorporates AMD 1 2016. (05/2016)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
    EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
    EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
    IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective