• Shopping Cart
    There are no items in your cart

EN 60077-3:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Railway applications - Electric equipment for rolling stock - Part 3: Electrotechnical components - Rules for d.c. circuit-breakers

Published date

03-05-2002

Superseded date

25-01-2022

Superseded by

EN IEC 60077-3:2019

Sorry this product is not available in your region.
Summarise this standard

1 Scope and object
2 Normative references
3 Definitions
   3.1 Components
   3.2 Component parts
   3.3 Operational features
   3.4 Breaking characteristics
4 Classification
5 Characteristics
   5.1 List of characteristics
   5.2 Type of circuit-breaker
   5.3 Rated values and limiting values for the main
       circuit
       5.3.1 General
       5.3.2 Rated voltages
       5.3.3 Rated currents
       5.3.4 Rated time constants
       5.3.5 Short-circuit characteristics
   5.4 Operational frequencies
   5.5 Electric and pneumatic control circuits
   5.6 Electric and pneumatic auxiliary circuits
   5.7 Over-current release
   5.8 Peak arc voltages
6 Product information
   6.1 Component documentation
   6.2 Marking
7 Normal service conditions
8 Constructional and performance requirements
   8.1 Constructional requirements
   8.2 Performance requirements
       8.2.1 Operating conditions
       8.2.2 Temperature rise
       8.2.3 Operation following inactivity
       8.2.4 Electromagnetic compatibility (EMC)
       8.2.5 Acoustic noise emission
       8.2.6 Dielectric properties
       8.2.7 Switching overvoltages
       8.2.8 Operational performance capability
       8.2.9 Ability to withstand vibration and shock
       8.2.10 Ability to make and break under short-circuit
              conditions
9 Tests
   9.1 Kinds of tests
       9.1.1 General
       9.1.2 Type tests
       9.1.3 Routine tests
       9.1.4 Investigatory tests
   9.2 Verification of constructional requirements
       9.2.1 General
       9.2.2 Type tests
       9.2.3 Routine tests
   9.3 Type tests for verification of performance
       requirements
       9.3.1 Test sequences
       9.3.2 General test conditions
       9.3.3 Test sequence I: general performance
              characteristics
       9.3.4 Test sequence II: rated short-circuit making
              and breaking capacities
       9.3.5 Test sequence III: capability to withstand
              vibration and shock
       9.3.6 Test sequence IV: searching for critical currents
       9.3.7 Test sequence V: climatic conditions
       9.3.8 Test sequence VI: other tests
   9.4 Routine tests for verification of performance
       requirements
       9.4.1 General
       9.4.2 Mechanical operation
       9.4.3 Calibration of releases
       9.4.4 Dielectric withstand
       9.4.5 Air-tightness (for pneumatic circuit-breaker)
Annex A (normative) Test circuit to verify the making and
        breaking capacities
Annex B (informative) Verification of short-circuit making
        and breaking capacities
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

In addition to the general requirements of EN 60077-2, it gives the rules for circuit-breakers, the main contacts of which are to be connected to d.c. power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V d.c. according to EN 60850.

Committee
CLC/TC 9X
DevelopmentNote
To be read in conjunction with EN 60077-1 and EN 60077-2. (10/2002)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Sorry this product is not available in your region.