• EN 60079-13:2017

    Current The latest, up-to-date edition.

    Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

    Available format(s): 

    Language(s): 

    Published date:  06-10-2017

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements for all rooms
    5 Clean air supply
    6 Requirements for pressurized rooms
    7 Requirements for artificially ventilated rooms
    8 Marking
    9 Instructions
    Annex A (informative) - Maintenance
    Annex B (informative) - Guidelines when pressurization
            or artificial ventilation is not immediately restored
    Annex C (informative) - Examples of applications and
            associated guidelines
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 60079-13:2017(E) gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer’s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer’s facility may include third-party verification. For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room "p" and artificially ventilated room "v" and should be considered as introducing all new requirements. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p";- addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv";- definition of the differences between pressurization and artificial ventilation types of protection;- removal of protection of rooms with an inert gas or a flammable gas from the scope of this document;- addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines. Additional information regarding the scope of this document can be found in Clause 1.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 31
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN EN 1473:2016-10 Installation and equipment for liquefied natural gas - Design of onshore installations
    BS EN 60079-29-2:2015 Explosive atmospheres Gas detectors. Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    BS EN 1473:2016 Installation and equipment for liquefied natural gas. Design of onshore installations
    DIN EN 1473:1997-11 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    I.S. EN 1473:2016 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
    PREN 1473 : DRAFT 2018 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    EN 1473:2016 Installation and equipment for liquefied natural gas - Design of onshore installations
    I.S. EN 60079-14:2014 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
    I.S. EN 60079-29-2:2015 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
    UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
    BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
    BS EN 60079-2:2014 Explosive atmospheres Equipment protection by pressurized enclosure \'p\'
    CEI EN 60079-29-2 : 2016 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
    UNE-EN 60079-2:2015 Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
    18/30369304 DC : DRAFT APR 2018 BS EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    UNE-EN 60079-29-2:2016 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    EN 60079-2:2014/AC:2015 EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014)
    EN 60079-29-2:2015 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60079-10-1:2015 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
    EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
    IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60079-10-1:2015 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
    IEC 61285:2015 Industrial-process control - Safety of analyser houses
    IEC TR 61831:2011 On-line analyser systems - Guide to design and installation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective