• EN 60297-3-108:2015

    Current The latest, up-to-date edition.

    Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-108: Dimensions of R-type subracks and plug-in units

    Available format(s): 

    Language(s): 

    Published date:  16-01-2015

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Arrangement overview
    5 RA - type subrack
    6 RB-type subrack
    7 R-type subrack guide rails
    8 Electromagnetic shielding provisions and
       mounting flanges
    9 Chassis integrated subrack
    10 Front panel/plug-in unit compatible with
       RA - type subrack
    11 Front panel/plug-in unit compatible with
       RB - type subrack
    12 Injector/extractor handle
    13 Printed board dimensions
    14 Dimensions
    15 Nomenclature
    Annex A (normative) - Mounting support
    Annex B (normative) - Environmental tests
    Annex C (normative) - Thermal management
    Annex D (informative) - Comparison of IEC 60297-3-101
            with IEC 60297-3-108
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 60297-3-108:2014 provides dimensions and features for R-type subracks and plug-in units, i.e. ruggedized variants of the mechanical structures of the 482,6 mm (19 in) series, with enhanced vibration and shock resistance and/or improved EMC performance, for use in more harsh environment. This leads to a subrack standard which is externally compatible with IEC 60297-3-100 but internally largely incompatible with IEC 60297-3-101. R-type subracks, chassis integrated subracks and plug-in units incorporate dimensions and features which provide for a higher level of ruggedness, compared with IEC 60297-3-101 (test set-up and load definitions are selected from IEC 61587-1 and IEC 61587-5).Key words: R-Type, Subracks, Plug-in unit

    General Product Information - (Show below) - (Hide below)

    Committee CLC/SR 48D
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 61587-1:2017 Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 series Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
    CEI EN 61587-1 : 2012 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION
    I.S. EN 61587-1:2017 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION
    EN 61587-1:2017 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60297-3-101:2004 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units
    IEC TS 62610-2:2011 Mechanical structures for electronic equipment - Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 series - Part 2: Design guide: Method for determination of forced air-cooling structure
    EN 60297-3-100:2009 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets
    EN 60297-3-105:2009 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-105: Dimensions and design aspects for 1U high chassis
    EN 61587-5:2014 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units
    IEC 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
    IEC 61587-1:2016 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
    IEC 61587-5:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units
    EN 60297-3-101:2004 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-101: Subracks and associated plug-in units
    EN 61587-1:2017 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
    IEC 60297-3-105:2008 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-105: Dimensions and design aspects for 1U high chassis
    EN 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
    IEC 60297-3-100:2008 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective