• EN 60317-46:2014

    Current The latest, up-to-date edition.

    Specifications for particular types of winding wires - Part 46: Aromatic polyimide enamelled round copper wire, class 240

    Available format(s): 

    Language(s): 

    Published date:  14-02-2014

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative reference
    3 Terms, definitions, general notes and appearance
    4 Dimensions
    5 Electrical resistance
    6 Elongation
    7 Springiness
    8 Flexibility and adherence
    9 Heat shock
    10 Cut-through
    11 Resistance to abrasion (nominal conductor diameters from
       0,250 mm up to and including 2,500 mm)
    12 Resistance to solvents
    13 Breakdown voltage
    14 Continuity of insulation
    15 Temperature index
    16 Resistance to refrigerants
    17 Solderability
    18 Heat or solvent bonding
    19 Dielectric dissipation factor
    20 Resistance to transformer oil
    21 Loss of mass
    23 Pin hole test
    30 Packaging
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 60317-46:2013 specifies the requirements of enamelled round copper winding wire of class 240 with a sole coating of aromatic polyimide resin. The range of nominal conductor diameters covered by this standard is: - grade 1: 0,020 mm up to and including 2,000 mm; - grade 2: 0,020 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - deletion of the 'in some countries' statement in the scope; - new subclause containing general notes on winding wire, formerly a part of the scope; - new subclause containing requirements for appearance; - revision to the notes in Clause 19, Dielectric dissipation factor; - new Clause 23, Pin-hole test. Keywords: requirements of enamelled round copper winding wire, class 240, sole coating of aromatic polyimide resin

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 55
    Development Note To be read in conjunction with EN 60317-0-1. (02/2014)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
    CEI EN 60317-50 : 2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200
    EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
    BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
    BS EN 61858-1:2014 Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS
    BS EN 61858:2008 Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS
    I.S. EN 60317-50:2012 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200 (IEC 60317-50:2012 (EQV))
    I.S. EN 61858-1:2014 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 1: WIRE-WOUND WINDING EIS
    UNE-EN 60317-50:2013 Specifications for particular types of winding wires - Part 50: Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200
    BS EN 60317-50:2012 Specifications for particular types of winding wires Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200
    I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
    EN 61858-1:2014 Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS
    EN 60317-50 : 2012 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200
    EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60317-0-1:2014 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire
    IEC 60317-0-1:2013 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire