• There are no items in your cart

EN 60318-1:2009

Current

Current

The latest, up-to-date edition.

Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones

Published date

23-12-2009

Sorry this product is not available in your region.

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Construction
5 Coupling of earphone to ear simulator
6 Calibration
7 Maximum permitted expanded uncertainty of
  measurements
Annex A (informative) - Lumped-parameter electrical
        network analogue of the ear simulator
Annex B (informative) - Example of one specific design of
        ear simulator
Annex C (informative) - Measurement method for the
        determination of the acoustical transfer impedance
        of the ear simulator
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

IEC 60318-1:2009 specifies an ear simulator for the measurement of supra-aural and circumaural earphones (used for example in audiometry and telephonometry) applied to the ear without acoustical leakage, in the frequency range from 20 Hz to 10 kHz. The same device can be used as an acoustic coupler at additional frequencies up to 16 kHz. This second edition cancels and replaces the first edition published in 1998 as well as replacing IEC 60318-2, published in 1998. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - an extension of the frequency range to 16 kHz; - a revised specification for the acoustical transfer impedance, including tolerances; - a method for measuring the acoustical transfer impedance; - expanded measurement uncertainties.

Committee
CLC/SR 29
DevelopmentNote
Supersedes EN 60318-2. (02/2010)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

BS EN 60118-0:2015 Electroacoustics. Hearing aids Measurement of the performance characteristics of hearing aids
12/30259067 DC : 0 BS EN 71-1:2011/A2 - SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES
BS EN 61842:2002 Microphones and earphones for speech communications
I.S. EN 60318-2:1999 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 2: AN INTERIM ACOUSTIC COUPLER FOR THE CALIBRATION OF AUDIOMETRIC EARPHONES IN THE EXTENDED HIGH-FREQUENCY RANGE
EN 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
05/30133728 DC : DRAFT MAY 2005 EN 71-1 - SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES
BS EN 60318-2:1998 Electroacoustics. Simulators of human head and ear An interim acoustic coupler for the calibration of audiometric earphones in the extended high-frequency range
UNE-EN 55024:2011 Information technology equipment - Immunity characteristics - Limits and methods of measurement
CEI EN 60645-1 : 2016 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY
BS EN 55024 : 2010 INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT
I.S. EN 60645-1:2017 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
CEI EN 60645-3 : 2008 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION
CEI EN 61842 : 2002 MICROPHONES AND EARPHONES FOR SPEECH COMMUNICATIONS
BS EN 60645-1:2017 Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry
BS EN 60645-3:2007 Electroacoustics. Audiometric equipment Test signals of short duration
I.S. EN 60645-3:2007 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION
UNE-EN 60645-1:2015 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry
IEC 61842:2002 Microphones and earphones for speech communications
I.S. EN 61842:2002 MICROPHONES AND EARPHONES FOR SPEECH COMMUNICATIONS
I.S. EN 55024:2010 INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT
EN 55024 : 2010 AMD 1 2015 INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 24:2010/A1:2015)
EN 60118-0:2015 Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids
EN 61842:2002 Microphones and earphones for speech communications
EN 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry

EN 61094-4:1995 Measurement microphones - Part 4: Specifications for working standard microphones
IEC 61094-4:1995 Measurement microphones - Part 4: Specifications for working standard microphones
IEC 61094-1:2000 Measurement microphones - Part 1: Specifications for laboratory standard microphones
ISO 389-8:2004 Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones
ISO 389-5:2006 Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz
ISO 389-1:1998 Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
IEC 61094-2:2009 Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
IEC 61094-6:2004 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.