A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

Withdrawn date

01-09-2007

Published date

15-11-2004

Sorry this product is not available in your region.

Specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in EN 60332-1-1. NOTE 1 Testing to EN 60332-1-2 may be performed simultaneously with that to EN 60332-1-3 if required. Recommended requirements for performance are given in Annex A. EN 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in EN 60332-2-2 is recommended. NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See EN 60332-3 series.) Has the status of a group safety publication in accordance with IEC Guide 104.

Committee
CLC/TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
NF EN 60332-1-2:2005 Identical
NF EN 60332-1-2/A12:2020 Identical
OVE EN 60332-1-2:2022 08 01 Identical
BS EN 61753-131-3:2011 Identical
PN-EN 60332-1-2:2010 Identical
UNE-EN 60332-1-2:2005 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.