• EN 60332-3-22:2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A

    Available format(s): 

    Superseded date:  29-01-2022

    Language(s): 

    Published date:  07-10-2009

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Definitions
    4 Test apparatus
    5 Test procedure
    6 Evaluation of test results
    7 Performance requirements
    8 Retest procedure
    9 Test report
    Annex A (normative) - Guidance on cable selection for
            type approval testing
    Annex B (informative) - Recommended performance
            requirements
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    EC 60332-3-22:2000 Specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. The test is intended for type approval testing. The requirements for the selection of cables for testing are given. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable's ability to limit flame spread. Covers category A and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 7 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the ladder, a standard or wide ladder being used for cables having a conductor cross-section greater than 35 mm2 according to the number of test pieces required, and a standard ladder for conductor cross-sections 35 mm2 and smaller. The category is intended for general use where high volumes of non-metallic material are required to be evaluated.A recommended performance requirement is also given.It has the status of a horizontal standard in accordance with IEC Guide 104.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 20
    Development Note Supersedes EN 50266-2-2. (11/2009)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    KTA 2101.3 : 2015(R2017) FIRE PROTECTION IN NUCLEAR POWER PLANTS - PART 3: FIRE PROTECTION OF MECHANICAL AND ELECTRICAL PLANT COMPONENTS
    EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
    BS EN 12601:2010 Reciprocating internal combustion engine driven generating sets. Safety
    DIN EN 12601:2011-07 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    EN 12601:2010 Reciprocating internal combustion engine driven generating sets - Safety
    UNI EN 12601 : 2011 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    I.S. EN 12601:2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    UNE-EN 12601:2011 Reciprocating internal combustion engine driven generating sets - Safety
    BS EN 60695-9-2:2014 Fire hazard testing Surface spread of flame. Summary and relevance of test methods

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
    EN 60332-3-10:2009 Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
    IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
    IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
    IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective