EN 60437:1997
Current
The latest, up-to-date edition.
Radio interference test on high-voltage insulators
14-10-1997
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Measurement frequency
5 Radio noise limits and test voltage
6 Measuring instruments
6.1 Standard CISPR measuring apparatus
6.2 Other measuring apparatus
7 Measuring circuit
8 Requirements for the test voltage
9 Atmospheric conditions
10 Test area
11 Arrangement of insulators for test
11.1 Mounting of insulators
11.2 Condition of insulators before test
12 Insulators for type test
12.1 Number of insulators
12.2 String insulator units
13 Procedure for type tests
13.1 Checking and calibration of test circuit
13.2 Voltage application and RI characteristics
13.3 Acceptance criterion
14 Procedure for sample tests
14.1 Insulators subject to sample tests
14.2 Number of samples
14.3 Mounting arrangement
14.4 Test procedure
14.5 Acceptance criterion
15 Test report
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Specifies the procedure for a radio interference (RI) test carried out in a laboratory on clean and dry insulators at a frequency of 0,5 MHz or 1 MHz or, alternatively, at other frequencies between 0,5 MHz and 2 MHz.
Committee |
CLC/SR 36
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
BS EN 60437:1998 | Identical |
NEN EN IEC 60437 : 1998 | Identical |
I.S. EN 60437:1999 | Identical |
UNE-EN 60437:1999 | Identical |
CEI EN 60437 : 1998 | Identical |
NF EN 60437 : 2000 | Identical |
PN EN 60437 : 2007 | Identical |
VDE 0674-6 : 1998 | Identical |
SN EN 60437 : 1997 | Identical |
NBN EN 60437 : 1998 | Identical |
IEC 60437:1997 | Identical |
DIN EN 60437 : 1998 | Identical |
DS EN 60437 : 1997 | Identical |
UNE-EN 50341-1:2017 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
12/30235264 DC : 0 | BS EN 50119:2009 AMD1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 50341-1:2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
VDE 0674-1 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
DIN EN 60168 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
CEI EN 50341-1 : 2013 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
12/30260570 DC : 0 | BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
PREN 50341-1 : DRAFT 2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-1:1996/A11:1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
EN 60168:1994/A2:2000 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1KV |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-2:1995 | Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.