Summarise this standard

1 Scope and object
2 Normative references
3 Terms and definitions
4 Preparation
  4.1 Test set-up
  4.2 Resources
  4.3 Preparation of the specimen and the calibrator
5 Method
  5.1 Conditioning
  5.2 Impedance regularity
  5.3 Operational attenuation of the connecting cables and the DUT
  5.4 Procedure
6 Evaluation of the effective transfer impedance
7 Details to be specified
8 Documentation
Annex A (informative) Screening attenuation calculation
      A.1 Objective
      A.2 Definition of screening attenuation of a connector screen
      A.3 Screening attenuation A[SC] in dB
Annex B (informative) Test set-up verification
      B.1 Objective
      B.2 Test set-up verification

Defines a test method intended to assess the screening effectiveness of screened non-circular multi-pole, electrically short, connectors by the measurement of the effective (surface) transfer impedance, using a network analyzer, for frequencies up to 1 GHz. Is based on the line injection test method.