EN 60522:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Determination of the permanent filtration of X-ray tube assemblies

Superseded date

31-01-2022

Superseded by

EN IEC 60522-1:2021

Published date

01-04-1999

Sorry this product is not available in your region.

FOREWORD
1 Scope and object
  1.1 Scope
  1.2 Object
2 Normative references
3 Terminology
  3.1 Degree of requirements
  3.2 Use of terms
  3.3 Defined terms
4 Measurement of permanent filtration
  4.1 General
  4.2 Test sample
  4.3 Generation of the x-ray beam for measurement
  4.4 Radiation detector
  4.5 Composition of reference materials
  4.6 Method of measurement
5 Indications and statements of permanent filtration
Annex A (normative) Terminology - Index of defined terms
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Defines the concept of permanent filtration in X-ray tube assemblies for medical diagnosis and radiotherapy and describes a method for its determination. It contains requirements for statements of compliance for accompanying documents and for markings on X-ray tube assemblies. Methods are given to determine the permanent filtration in an X-ray tube assembly with an accuracy that is sufficient to enable the appropriate additional filtration to be provided in order to attain the desired total filtration.

Committee
CLC/TC 62
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
NF EN 60522 : 2003 Identical
SN EN 60522 : 1999 Identical
PN EN 60522 : 2002 Identical
UNE-EN 60522:2000 Identical
BS EN 60522:1999 Identical
NBN EN 60522 : 1999 Identical
I.S. EN 60522:1999 Identical
CEI EN 60522 : 2001 Identical
NEN EN IEC 60522 : 1999 Identical
IEC 60522:1999 Identical
DIN EN 60522:2002-06 Identical
IEC 60522:1976 Identical

EN 60601-2-28:2010 Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
BS EN 61223-3-4:2000 Evaluation and routine testing in medical imaging departments Acceptance tests
BS EN 60601-2-68:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
CEI EN 60601-2-28 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-28: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS
BS EN 60601-2-28:2010 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
I.S. EN 60601-1-3:2008 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT
EN 60601-1-3 : 2008 AMD 11 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008/A1:2013)
I.S. EN 60601-2-28:2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-28: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS
EN 60601-2-68:2015 Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
BS EN 60601-1-3 : 2008 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008)
UNE-EN 60601-1-3:2008 Medical electrical equipment- Part 1-3: General requirements for basic safety and essential performance- Collateral Standard: Radiation protection in diagnostic X-ray equipment

EN 60601-1-3 : 2008 AMD 11 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008/A1:2013)
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
ISO 2092:1981 Light metals and their alloys Code of designation based on chemical symbols
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
HD 501 : 200S1 MEDICAL RADIOLOGY - TERMINOLOGY