EN 60613:2010
Current
The latest, up-to-date edition.
Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis
16-04-2010
1 Scope
2 Normative references
3 Terms and definitions
4 Presentation of the electrical characteristic
5 LOADING of an X-RAY TUBE
6 Input power
7 RADIOGRAPHIC RATINGS
8 Presentation of data
Annex A (informative) - Rationale and historical background
Annex B (informative) - Measurement of the X-RAY TUBE CURRENT
Bibliography
Index of defined terms
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 60613:2010 applies to X-ray tube assemblies either with a rotating anode X-ray tube or a stationary anode X-ray tube, intended for use in medical diagnosis. For an X-ray tube head, its X-ray tube assembly aspects are also within the scope. IEC 60613:2010 covers performance-related definitions and conditions of electrical and loading characteristics of X-ray tube assemblies in relation to their behaviour during and after energization and, where appropriate, methods of presentation and measurement of these characteristics. This International Standard is therefore relevant for the manufacturer and the responsible organization. This third edition cancels and replaces the second edition of IEC 60613, published in 1989. It constitutes a technical revision. This third edition has been adapted to apply to the present technology.
Committee |
CLC/TC 62
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 60613 : 2010 | Identical |
UNE-EN 60613:1993 | Identical |
IEC 60613:2010 | Identical |
NBN EN 60613 : 2010 | Identical |
NEN 10613 : 1991 | Identical |
NEN EN IEC 60613 : 2010 | Identical |
I.S. EN 60613:2010 | Identical |
PN EN 60613 : 2010 | Identical |
SN EN 60613 : 1990 | Identical |
BS EN 60613:2010 | Identical |
CEI EN 60613 : 2010 | Identical |
DIN EN 60613:2011-07 | Identical |
UNE-EN 60613:2010 | Identical |
PNE-FprEN 60613 | Identical |
BS EN 61158-3-14:2014 | Identical |
DIN 6814-3:2016-08 | TERMS IN THE FIELD OF RADIOLOGICAL TECHNIQUE - PART 3: DOSIMETRY |
EN 60601-2-28:2010 | Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
CEI EN 60601-2-28 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-28: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS |
BS EN 60601-2-28:2010 | Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
EN 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
I.S. EN 60336:2005 | MEDICAL ELECTRICAL EQUIPMENT - X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS - CHARACTERISTICS OF FOCAL SPOTS |
BS EN 60336:2005 | Medical electrical equipment. X-ray tube assemblies for medical diagnosis. Characteristics of focal spots |
UNE-EN 60601-2-44:2010 | Medical electrical equipment -- Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography |
BS EN 60601-2-45 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES |
I.S. EN 60601-2-28:2010 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-28: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS |
I.S. EN 60601-2-45:2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES |
CEI EN 60336 : 2006 | MEDICAL ELECTRICAL EQUIPMENT X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS CHARACTERISTICS OF FOCAL SPOTS |
EN 60601-2-45:2011/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES (IEC 60601-2-45:2011/A1:2015) |
EN 60601-1-3 : 2008 AMD 11 2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008/A1:2013) |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.