    FOREWORD
    1 Scope
    2 Normative references
    3 Definitions
    4 General requirements
    5 General notes on tests
    6 Ratings
    7 Classification
    8 Marking
    9 Checking of dimensions
    10 Protection against electric shock
    11 Provision for earthing
    12 Terminals
    13 Constructional requirements
    14 Mechanism
    15 Resistance to ageing, protection provided by
       enclosures of switches and resistance to
       humidity
    16 Insulation resistance and electric strength
    17 Temperature rise
    18 Making and breaking capacity
    19 Normal operation
    20 Mechanical strength
    21 Resistance to heat
    22 Screws, current-carrying parts and connections
    23 Creepage distances, clearances and distances
       through sealing compound
    24 Resistance of insulating material to abnormal
       heat, to fire and to tracking
    25 Resistance to rusting
    26 EMC requirements
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications
    Annex ZB (normative) - Special national conditions
    Annex ZC (informative) - A-deviations

    Abstract - (Show below) - (Hide below)

    IEC 60669-2-6:2012 is applicable to fireman's switches used for the breaking of the low-voltage circuits for exterior and interior signs and luminaires e.g. neon signs for a.c. only with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A. This publication is to be read in conjunction with IEC 60669-1:1998.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes EN 50425. (03/2012) To be read in conjunction with EN 60669-1. (04/2012) Supersedes UNE EN 50425. (02/2015)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    S.R. HD 60364-5-537:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
    HD 60364-5-537:2016/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
    UNE-HD 60364-5-537:2017 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
    EN 50107-1 : 2002 AMD 1 2004 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
    IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
    IEC 60669-2-4:2004 Switches for household and similar fixed electrical installations - Part 2-4: Particular requirements - Isolating switches
    EN 50107-2:2005 Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV - Part 2: Requirements for earth-leakage and open-circuit protective devices
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective