• Shopping Cart
    There are no items in your cart

EN 60695-2-4/1:1993/A1:1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

FIRE HAZARD TESTING - TEST METHODS - KW NOMINAL PREMIXED TEST FLAME AND GUIDANCE

Published date

12-01-2013

Superseded date

13-11-2003

Superseded by

EN 60695-11-2:2017

Sorry this product is not available in your region.
Summarise this standard

Cooperating organizations
National foreword
Foreword
Introduction
1. Scope
2. Normative references
3. Definition
4. Requirements
5. Production and confirmation of the test flame
5.1 Production
5.2 Confirmation
5.3 Apparatus
6. Recommended arrangements for use of the test flame
7. Classification and designation
Figures
Annexes
A. Examples of test arrangements
ZA. (normative) Other international publications quoted
     in this standard with the references of the relevant
     European publications
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references

Gives the detailed requirements for the production of the 1 kW nominal, propane based pre-mixed type test flame. The approximate overall flame height is 175 mm. Also includes detailed definitions and diagrams.

DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Sorry this product is not available in your region.