EN 60811-405:2012
Current
The latest, up-to-date edition.
Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths
15-06-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 60811-405:2012 specifies the procedure for the thermal stability test which applies to PVC compounds. IEC 60811-405:2012 cancels and replaces Clause 9 of IEC 60811-3-2:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012. This publication is to be read in conjunction with IEC 60811-100:2012.
| Committee |
CLC/TC 20
|
| DevelopmentNote |
To be read in conjunction with EN 60811-100. Supersedes EN 60811-3-2. (06/2012)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| VDE 0473-811-405 : 2012 | Identical |
| BS EN 60811-405:2012 | Identical |
| NEN EN IEC 60811-405 : 2012 | Identical |
| PN EN 60811-405 : 2012 | Identical |
| CEI EN 60811-405 : 2014 | Identical |
| DIN EN 60811-405 : 2012 | Identical |
| I.S. EN 60811-405:2012 | Identical |
| IEC 60811-405:2012 | Identical |
| NF EN 60811-405 : 2012 | Identical |
| UNE-EN 60811-405:2012 | Identical |
| BS EN 63044-1:2017 | Identical |
| ISO 695:1991 | Glass — Resistance to attack by a boiling aqueous solution of mixed alkali — Method of test and classification |
| ISO 1776:1985 | Glass — Resistance to attack by hydrochloric acid at 100 degrees C — Flame emission or flame atomic absorption spectrometric method |
| EN 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
| IEC 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
| ISO 719:1985 | Glass — Hydrolytic resistance of glass grains at 98 degrees C — Method of test and classification |
| IEC 60811-3-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test |