• EN 60947-3:2009

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units

    Available format(s): 

    Withdrawn date:  01-05-2012

    Language(s): 

    Published date:  05-06-2009

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Abstract - (Show below) - (Hide below)

    IEC 60947-3:2008 applies to switches, disconnectors, switch-disconnectors and fuse-combination units to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V a.c. or 1 500 V d.c. This part does not apply to equipment coming within the scope of IEC 60947-2, IEC 60947-4-1 and IEC 60947-5-1; however, when switches and fuse-combination units coming into the scope of this part are normally used to start, accelerate and/or stop an individual motor they shall also comply with the additional requirements given in Annex A. The requirements for single pole operated three pole switches are included in Annex C. Auxiliary switches fitted to equipment within the scope of this part shall comply with the requirements of IEC 60947-5-1. This part does not include the additional requirements necessary for electrical apparatus for explosive gas atmospheres. This edition includes the following significant technical changes with respect to the previous edition: - alignment with the fifth edition of IEC 60947-1; - a switching operation without current allowed between making and breaking operation (Table 3); - increased number of operations for AC-23 allowed with agreement of the manufacturer (Table 3); - simplified test procedure amended, f) added to 8.3.2.1.3; - temperature rise test shall be made at the rated operational current /e instead of the conventional enclosed thermal current /the (8.3.3.1).

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 121A
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Withdrawn
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective