• EN 61010-2-010:2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of Materials

    Available format(s): 

    Superseded date:  11-06-2020

    Language(s): 

    Published date:  07-11-2014

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
    3 Terms and definitions
    4 Tests
    5 Marking and documentation
    6 Protection against electric shock
    7 Protection against mechanical HAZARDS
    8 Resistance to mechanical stresses
    9 Protection against the spread of fire
    10 Equipment temperature limits and resistance to heat
    11 Protection against HAZARDS from fluids
    12 Protection against radiation, including laser sources,
       and against sonic and ultrasonic pressure
    13 Protection against liberated gases and substances,
       explosion and implosion
    14 Components and subassemblies
    15 Protection by interlocks
    16 HAZARDS resulting from application
    17 RISK Assessment
    Annexes
    Annex K
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 61010-2-010:2014 specifies safety requirements for electrically powered laboratory equipment for the heating of materials, where the heating of materials is one of the functions of the equipment. This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and includes the following significant changes from the second edition, as well as numerous other changes:- added a definition for HEAT TRANSFER MEDIUM to Clause 3; - added a symbol for FLAMMABLE LIQUID to Table 1 in Clause 5;- added a requirement for instructions pertaining to ventilation in Clause 5;- modified the requirements for humidity preconditioning in Clause 6;- added requirements for equipment containing or using flammable liquids to Clause 9;- added requirements for over-temperature protection devices to Clause 10.It has the status of a group safety publication in accordance with IEC Guide 104.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 66X
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 62353:2014 Medical electrical equipment. Recurrent test and test after repair of medical electrical equipment
    PD 6632:1998 Biotechnology. Laboratories for research, development and analysis. Guidance on the selection of equipment needed for biotechnology laboratories according to the degree of hazard
    EN 62353:2014 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
    BS EN 61010-2-040:2015 Safety requirements for electrical equipment for measurement, control, and laboratory use Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
    EN 61010-2-051:2015 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
    VDE 0411-114 : 1996 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PARTICULAR REQUIREMENTS FOR LABORATORY EQUIPMENT FOR MIXING AND STIRRING
    EN 61010-2-040:2015 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040 Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
    BS EN 61010-2-051:2015 Safety requirements for electrical equipment for measurement, control and laboratory use Particular requirements for laboratory equipment for mixing and stirring
    I.S. EN 61010-2-040:2015 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-040: PARTICULAR REQUIREMENTS FOR STERILIZERS AND WASHER-DISINFECTORS USED TO TREAT MEDICAL MATERIALS

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 7010:2011 Graphical symbols Safety colours and safety signs Registered safety signs
    DIN 12876-1:2001-12 ELECTRICAL LABORATORY DEVICES - LABORATORY CIRCULATORS AND BATHES - PART 1: TERMS AND CLASSIFICATION
    EN ISO 7010 : 2012 AMD 7 2017 GRAPHICAL SYMBOLS - SAFETY COLOURS AND SAFETY SIGNS - REGISTERED SAFETY SIGNS (ISO 7010:2011/AMD 7:2016)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective