• EN 61010-2-101:2017

    Current The latest, up-to-date edition.

    Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment

    Available format(s): 

    Language(s): 

    Published date:  24-02-2017

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Abstract - (Show below) - (Hide below)

    IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety function, as specified in IEC Guide 104. This standard has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This second edition cancels and replaces the first edition published in 2002. It constitutes a technical revision and includes the following significant changes from the first edition, as well as numerous other changes:- excluded IEC 61010-2-081 (general laboratory equipment) from the scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment;- updated Biohazard and Lot symbols in Table 1 in Clause 5;- added requirement for within expiration consumables and authorized representative details in Instructions for Use to Clause 5;- added requirement for gas or liquid markings and ratings to Clause 5;- added requirement to include OPERATOR instructions to deal with consumable or sample spills, jams or breakage inside equipment, disposal of hazardous waste, personal protection, RISK reduction procedures relating to flammable liquids, burns from surfaces, and loading and unloading of sample and reagents in Instructions for Use to Clause 5; - added requirement for manufacturer to provide instructions on equipment transport, storage and removal from use to Clause 5;- added normative reference ISO 18113-5 for instructions for use of self-test IVD medical equipment in Clause 5;- added requirement for OPERATOR maintenance instructions to Clause 7;- added requirements for sample zones and loading zones to Clause 7;- excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8;- added requirement for biohazard marking to Clause 13;- added requirement for interlock systems containing electric/electronic or programmable components to Clause 15;- added informative reference to Usability standard IEC 62366 to Clause 16;- replaced Clause 17 with requirements of ISO 14971 for RISK assessment.- Annex BB Instructions for use for self-testing IVD Medical Equipment deleted and a reference given to ISO 18113-5 in Clause 5.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 66X
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN ISO 15197:2015 IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEMS FOR SELF-TESTING IN MANAGING DIABETES MELLITUS (ISO 15197:2013)
    ISO 15197:2013 In vitro diagnostic test systems — Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus
    EN ISO 15197:2015 In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013)
    UNE-EN ISO 15197:2015 In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013)

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 4169 : 2016 : REDLINE Standard Practice for Performance Testing of Shipping Containers and Systems
    EN ISO 13857:2008 Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs (ISO 13857:2008)
    ISO 13857:2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs
    EN ISO 14971:2012 Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01)
    ISO 14971:2007 Medical devices Application of risk management to medical devices
    ISO 18113-5:2009 In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 5: In vitro diagnostic instruments for self-testing
    EN ISO 18113-5:2011 In vitro diagnostic medical devices - Information supplied by the manufacturer (labelling) - Part 5: In vitro diagnostic instruments for self-testing (ISO 18113-5:2009)
    ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
    EN 980:2008 Symbols for use in the labelling of medical devices