EN 61094-6:2005
Current
The latest, up-to-date edition.
Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
11-01-2005
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Principle of electrostatic actuator operation
5.1 General
5.2 Electrostatic pressure
5.3 Electrostatic actuator response
6 Actuator design
6.1 General
6.2 Design
7 Validation
7.1 General
7.2 Repeatability of measurements
7.3 Uniformity of actuators of a given model
7.4 Uniformity of the difference between actuator and
pressure response levels
8 Measurement of electrostatic actuator response
8.1 System for measurement of electrostatic actuator
response
8.2 Uncertainty components
9 Applications of an electrostatic actuator
9.1 General
9.2 Verification of the frequency response of a measurement
system
9.3 Determination of the environmental characteristics of
microphone measurement systems
9.4 Determination of free-field and pressure frequency
responses
9.5 Measurement of actuator response at very high
frequencies
Annex A (informative) Examples of electrostatic actuator
designs
Annex B (informative) Set-up for measuring electrostatic
actuator response
Annex C (informative) Typical uncertainty analysis
Annex D (informative) Difference between free-field-,
pressure- and actuator responses
for typical models of measurement
microphones
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Figures
Table
This part of EN 61094 - gives guidelines for the design of actuators for microphones equipped with electrically conductive diaphragms; - gives methods for the validation of electrostatic actuators; - gives a method for determining the electrostatic actuator response of a microphone. The applications of electrostatic actuators are not fully described within this standard but may include - a technique for detecting changes in the frequency response of a microphone, - a technique for determining the environmental influence on the response of a microphone, - a technique for determining the free field or pressure response of a microphone without specific acoustical test facilities, by the application of predetermined correction values specific to the microphone model and actuator used, - a technique applicable at high frequencies not typically covered by calibration methods using sound excitation.
Committee |
CLC/SR 29
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI EN 61094-6 : 2005 | Identical |
PN EN 61094-6 : DEC 2005 | Identical |
UNE-EN 61094-6:2008 | Identical |
NBN EN 61094-6 : 2006 | Identical |
I.S. EN 61094-6:2005 | Identical |
DIN EN 61094-6:2005-05 | Identical |
BS EN 61094-6:2005 | Identical |
NEN EN IEC 61094-6 : 2005 | Identical |
NF EN 61094-6 : 2005 | Identical |
IEC 61094-6:2004 | Identical |
BS EN 61672-3:2013 | Electroacoustics. Sound level meters Periodic tests |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 62585 : 2012 | ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012) |
EN 61672-3:2013 | Electroacoustics - Sound level meters - Part 3: Periodic tests |
EN 61094-8:2012/AC:2013 | Measurement microphones — Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
CEI EN 61672-1 : 2014 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 1: SPECIFICATIONS |
I.S. EN 61672-3:2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 3: PERIODIC TESTS |
BS EN 61094-8:2012 | Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison |
I.S. EN 61672-1:2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 1: SPECIFICATIONS |
CEI EN 61094-8 : 2013 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 8: METHODS FOR FREE-FIELD CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON |
BS EN 61672-1:2013 | Electroacoustics. Sound level meters Specifications |
CEI EN 61672-3 : 2014 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 3: PERIODIC TESTS |
UNE-EN 60318-1:2010 | Electroacoustics - Simulators of human head and ear -- Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones |
BS EN 62585:2012 | Electroacoustics. Methods to determine corrections to obtain the free-field response of a sound level meter |
CEI EN 62585 : 2013 | ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER |
UNE-EN 61094-8:2013 | Measurement microphones. Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
UNE-EN 62585:2013 | Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter |
I.S. EN 61094-8:2012 | MEASUREMENT MICROPHONES - PART 8: METHODS FOR DETERMINING THE FREE-FIELD SENSITIVITY OF WORKING STANDARD MICROPHONES BY COMPARISON (IEC 61094-8:2012 (EQV)) |
IEC 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
EN 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
IEC 61094-3:2016 | Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
EN 61094-3:2016/AC:2017-01 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.