EN 61094-6:2005
Current
The latest, up-to-date edition.
Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
11-01-2005
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Principle of electrostatic actuator operation
5.1 General
5.2 Electrostatic pressure
5.3 Electrostatic actuator response
6 Actuator design
6.1 General
6.2 Design
7 Validation
7.1 General
7.2 Repeatability of measurements
7.3 Uniformity of actuators of a given model
7.4 Uniformity of the difference between actuator and
pressure response levels
8 Measurement of electrostatic actuator response
8.1 System for measurement of electrostatic actuator
response
8.2 Uncertainty components
9 Applications of an electrostatic actuator
9.1 General
9.2 Verification of the frequency response of a measurement
system
9.3 Determination of the environmental characteristics of
microphone measurement systems
9.4 Determination of free-field and pressure frequency
responses
9.5 Measurement of actuator response at very high
frequencies
Annex A (informative) Examples of electrostatic actuator
designs
Annex B (informative) Set-up for measuring electrostatic
actuator response
Annex C (informative) Typical uncertainty analysis
Annex D (informative) Difference between free-field-,
pressure- and actuator responses
for typical models of measurement
microphones
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Figures
Table
This part of EN 61094 - gives guidelines for the design of actuators for microphones equipped with electrically conductive diaphragms; - gives methods for the validation of electrostatic actuators; - gives a method for determining the electrostatic actuator response of a microphone. The applications of electrostatic actuators are not fully described within this standard but may include - a technique for detecting changes in the frequency response of a microphone, - a technique for determining the environmental influence on the response of a microphone, - a technique for determining the free field or pressure response of a microphone without specific acoustical test facilities, by the application of predetermined correction values specific to the microphone model and actuator used, - a technique applicable at high frequencies not typically covered by calibration methods using sound excitation.
| Committee |
CLC/SR 29
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| CEI EN 61094-6 : 2005 | Identical |
| PN EN 61094-6 : DEC 2005 | Identical |
| NBN EN 61094-6 : 2006 | Identical |
| I.S. EN 61094-6:2005 | Identical |
| DIN EN 61094-6:2005-05 | Identical |
| BS EN 61094-6:2005 | Identical |
| NEN EN IEC 61094-6 : 2005 | Identical |
| NF EN 61094-6 : 2005 | Identical |
| IEC 61094-6:2004 | Identical |
| UNE-EN 61094-6:2008 | Identical |