EN 61753-091-3:2004
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Fibre optic interconnecting devices and passive components performance standard - Part 091-3: Single-mode fibre optic pigtailed style circulators for category U - Uncontrolled environment
01-09-2007
22-10-2004
1 Scope
2 Normative references
3 Test
4 Test report
5 Performance requirements
5.1 Sample size, sequencing and grouping
5.2 Test details and requirements
Annex A (normative) Sequencing and grouping of tests
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Contains the minimum requirements and severities which a fibre optic circulator shall satisfy in order to be categorised as meeting the requirements of circulator devices used in uncontrolled environments. The requirements cover non-connectorised single mode circulators for category U - Uncontrolled environments.
Committee |
CLC/TC 86BXA
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
PN EN 61753-091-3 : 2005 | Identical |
DIN EN 61753-091-3:2005-04 | Identical |
NBN EN 61753-091-3 : 2006 | Identical |
NF EN 61753-091-3 : 2005 | Identical |
BS EN 61753-091-3:2004 | Identical |
CEI EN 61753-091-3 : 2005 | Identical |
NEN EN IEC 61753-091-3 : 2004 | Identical |
UNE-EN 61753-091-3:2004 | Identical |
I.S. EN 61753-091-3:2004 | Identical |
IEC 61753-091-3:2004 | Identical |
PNE-prEN 61753-091-3 | Identical |
EN 61300-2-5:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examination and measurements - Polarization dependent loss in a single-mode fibre optic device |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-4:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 60793-1-1:2017 | Optical fibres - Part 1-1: Measurement methods and test procedures - General and guidance |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-2-14:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
IEC 61300-3-5:2000 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-5: Examinations and measurements - Wavelength dependence of attenuation |
IEC 61753-2-1:2000 | Fibre optic interconnecting devices and passive components performance standard - Part 2-1: Fibre optic connectors terminated on single-mode fibre for category U - Uncontrolled environment |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examinations and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-14:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-3-5:2001 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-5: Examinations and measurements - Wavelength dependence of attenuation |
EN 61753-2-1:2000 | Fibre optic interconnecting devices and passive components performance standard - Part 2-1: Fibre optic connectors terminated on single-mode fibre for category U - Uncontrolled environment |
IEC 61300-3-32:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-32: Examinations and measurements - Polarization mode dispersion measurement for passive optical components |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.