1 Scope
2 Normative references
3 Test
4 Test report
5 Performance requirements
5.1 Sample size, sequencing and grouping
5.2 Test details and requirements
Annex A (informative) Examples of attenuation requirements
of 1XN and 2XN branching devices
Annex B (normative) Sample size, sequencing and
grouping
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Specifies the minimum initialisation test and measurement requirements and severities for a branching device. The requirements cover balanced non-connectorised single-mode 1xN and 2xN non-wavelength-selective branching devices (N is the number of output ports).
Committee |
CLC/TC 86BXA
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
PN EN 61753-2-3 : 2004 | Identical |
NEN EN IEC 61753-2-3 : 2001 | Identical |
UNE-EN 61753-2-3:2001 | Identical |
DIN EN 61753-2-3:2002-08 | Identical |
IEC 61753-2-3:2001 | Identical |
BS EN 61753-2-3:2001 | Identical |
I.S. EN 61753-2-3:2002 | Identical |
NBN EN 61753 2-3 : 2002 | Identical |
CEI EN 61753-2-3 : 2002 | Identical |
IEC 61300-2-45:1999 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-45: Tests - Durability test by water immersion |
IEC 61300-3-20:2001 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-20: Examinations and measurements - Directivity of fibre optic branching devices |
IEC 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examination and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-2-14:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
IEC 61300-3-5:2000 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-5: Examinations and measurements - Wavelength dependence of attenuation |
IEC 61300-2-26:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
IEC 61753-2-1:2000 | Fibre optic interconnecting devices and passive components performance standard - Part 2-1: Fibre optic connectors terminated on single-mode fibre for category U - Uncontrolled environment |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-19:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
IEC 61300-2-27:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27: Tests - Dust - Laminar flow |
IEC 61300-2-28:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-28: Tests - Corrosive atmosphere (sulphur dioxide) |