Fibre optic sensors - Part 2-2: Temperature measurement - Distributed sensing
06-10-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General test setups for measurement
of performance parameters
5 Measurement procedures for performance
parameters
Annex A (informative) - Measurement parameter
performance table
Annex B (informative) - Point defect effects
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 61757-2-2:2016(E) defines detail specifications for distributed temperature measurement by a fibre optic sensor, also known as fibre optic distributed temperature sensing (DTS). DTS includes the use of Raman scattering, Brillouin scattering and Rayleigh scattering effects. In addition, Raman scattering and Rayleigh scattering based measurements are performed with a single-ended fibre configuration only. Brillouin scattering based measurements are performed with a single-ended fibre or fibre loop configuration. The technique accessible from both sides at same time (e. g. Brillouin optical time domain analysis, BOTDA) is referred to here as a loop configuration. Generic specifications for fibre optic sensors are defined in IEC 61757-1:2012. This part of IEC 61757 specifies the most important DTS performance parameters and defines the procedures for their determination. In addition to the group of performance parameters, a list of additional parameters has been defined to support the definition of the measurement specifications and their associated test procedures. The definitions of these additional parameters are provided for informational purposes and should be included with the sets of performance parameters. A general test setup is defined in which all parameters can be gathered through a set of tests. The specific tests are described within the clause for each measurement parameter. This general test setup is depicted and described in Clause 4 along with a list of general information that should be documented based upon the specific DTS instrument and test setup used to measure these parameters as per IEC 61757-2-2. Annex A provides a blank performance parameter table which should be used to record the performance parameter values for a given DTS instrument and chosen optical test setup configuration. Annex B provides guidelines for optional determination of point defect effects.
Keywords: fibre optic distributed temperature sensing (DTS)
This publication is to be read in conjunction with IEC 61757-1:2012
Committee |
CLC/SR 86C
|
DevelopmentNote |
To be read in conjunction EN 61757-1. (11/2017)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 61757-2-2:2017 | Identical |
UNE-EN 61757-2-2:2017 | Identical |
NEN EN IEC 61757-2-2 : 2017 | Identical |
OVE EN 61757-2-2 : 2018 08 01 | Identical |
CEI EN 61757-2-2 : 2018 | Identical |
DIN EN 61757-2-2:2018-06 | Identical |
SS-EN 61757-2-2:2018 | Identical |
PN EN 61757-2-2 : 2018 | Identical |
SN EN 61757-2-2:2017 | Identical |
I.S. EN 61757-2-2:2017 | Identical |
BS EN 61757-2-2:2017 | Identical |
PNE-FprEN 61757-3-1 | Identical |
IEC 61757-1:2012 | Fibre optic sensors - Part 1: Generic specification |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
IEC TR 61931:1998 | Fibre optic - Terminology |
EN 61757-1 : 2012 | FIBRE OPTIC SENSORS - PART 1: GENERIC SPECIFICATION (IEC 61757-1:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.