• Shopping Cart
    There are no items in your cart

EN 61811-50:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality

Superseded date

01-03-2015

Superseded by

EN 61811-1:2015

Published date

28-05-2002

Sorry this product is not available in your region.

1 General
  1.1 Scope
  1.2 Normative references
  1.3 Terms and definitions
  1.4 Preferred values
  1.5 Marking and documentation
2 Quality assessment procedures
  2.1 Primary stage of manufacture
  2.2 Structurally similar relays
  2.3 Subcontracting
  2.4 Qualification approval procedures
  2.5 Quality conformance inspection
  2.6 Test schedule
  2.7 Order of tests
3 Preparation of blank detail and detail specifications
4 Test schedule
  4.1 Test sequence
  4.2 Types of relays, based upon environmental
      protection (relay technology RT)
  4.3 Categories of application of contacts
  4.4 Notes relative to Table 1
5 Relay reliability - Failure rate data
Annex A (informative) Data base for failure rates
Annex ZA (normative) Normative references to international
                      publications with their corresponding
                      European publications

Is a sectional specification applicable to electromechanical all-or-nothing telecom relays of assessed quality. Selects the appropriate methods of test to be used in detail specifications and contains basic test schedules to be used in the preparation of such specifications.

Committee
CLC/SR 94
DevelopmentNote
Supersedes EN 116500 (09/2002)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

BS EN 61811-51:2002 Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Non-standardized types and construction
BS EN 61811-54:2002 Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 15 mm x 7,5 mm base
EN 61811-51:2002 Electromechanical all-or-nothing relays - Part 51: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Non-standardized types and construction
EN 61811-54:2002 Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base
I.S. EN 61811-53:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 53: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 14 MM X 9 MM BASE
I.S. EN 61811-52:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 52: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 20 MM X 10 MM BASE
BS EN 61811-52:2002 Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 20 mm x 10 mm base
BS EN 61811-53:2002 Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 14 mm x 9 mm base
BS EN 61811-55:2002 Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 11 mm x 7,5 mm (max.) base
IEC 61811-54:2002 Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base
EN 61811-52:2002 Electromechanical all-or-nothing relays - Part 52: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 20 mm x 10 mm base
I.S. EN 61811-51:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 51: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - NON-STANDARDIZED TYPES AND CONSTRUCTION
I.S. EN 61811-55:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 55: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 11 MM X 7,5 MM (MAX.) BASE
I.S. EN 61811-54:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 54: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 15 MM X 7,5 MM BASE
EN 61811-55:2002 Electromechanical all-or-nothing relays - Part 55: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 11 mm x 7,5 mm (max.) base
EN 61811-53:2002 Electromechanical all-or-nothing relays - Part 53: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 14 mm x 9 mm base

EN 60255-23:1996 Electrical relays - Part 23: Contact performance
IEC 61810-5:1998 Electromechanical non-specified time all-or-nothing relays - Part 5: Insulation coordination
IECQ 001002-3:2005 IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ) - RULES OF PROCEDURE - PART 3: APPROVAL PROCEDURES
CECC 00800 : 1986 CODE OF PRACTICE ON THE USE OF THE PPM APPROACH IN ASSOCIATION WITH THE CECC SYSTEM
IEC 61810-1:2015 Electromechanical elementary relays - Part 1: General and safety requirements
IEC 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
EN 61810-5 : 1998 ELECTROMECHANICAL NON-SPECIFIED TIME ALL-OR-NOTHING RELAYS - INSULATION COORDINATION
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
ISO 8601:2004 Data elements and interchange formats Information interchange Representation of dates and times
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
IEC 60062:2016 Marking codes for resistors and capacitors
CECC 00016 : 1990 BASIC SPECIFICATION - BASIC REQUIREMENTS FOR THE USE OF STATISTICAL PROCESS CONTROL (SPC) IN THE CECC SYSTEM
EN 60062:2016/AC:2016-12 MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016)
ISO 9001:2015 Quality management systems — Requirements
IEC 61811-1:2015 Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification
IEC 60255-23:1994 Electrical relays - Part 23: Contact performance
EN 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
EN 60695-2-2:1994/A1:1995 FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST
EN 61811-1:2015 Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.