EN 61847:1998
Current
The latest, up-to-date edition.
Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics
24-02-1998
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 List of symbols
5 General measurement requirements
5.1 Operating conditions
5.2 Load conditions
5.3 Preparation for measurements
6 Measurement procedures
6.1 Primary tip vibration excursion
6.2 Secondary tip vibration excursion
6.3 Drive frequency
6.4 Tip vibration frequency
6.5 Derived output acoustic power and output acoustic
power
6.6 Directivity pattern
6.7 Primary tip vibration excursion modulation
6.8 Duty cycle
6.9 Quiescent electrical power
6.10 Maximum electrical power
6.11 Primary acoustic output area
6.12 Secondary acoustic output area
6.13 Power reserve index
7 Declaration of output characteristics
Figures
Annexes
A Measurement methods and conditions
B Theory of operation of ultrasonic surgical devices
C Bibliography
ZA Normative reference to international publications with
their corresponding European publications
This standard specifies: - the essential non-thermal output characteristics of ultrasonic surgical units; - methods of measurement ot these output characteristics; - those characteristics which should be declared by the manufacturers of such equipment. This standard is applicable to equipment which meets the requirements of a, b and c below: a) ultrasonic surgical systems operating in the frequency range 20 kHz to 60 kHz; and b) ultrasonic surgical systems, whose use is the fragmentation or cutting of human tissue, whether or not those effects are delivered in conjunction with tissue removal or coagulation; and c) ultrasonic surgical systems, in which an acoustic wave is conducted by means of a specifically designed wave guide to deliver energy to the surgical site.
Committee |
CLC/SR 87
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI EN 61847 : 1999 | Identical |
SN EN 61847 : 1998 | Identical |
DIN EN 61847:1998-09 | Identical |
NEN EN IEC 61847 : 1998 | Identical |
IEC 61847:1998 | Identical |
PN EN 61847 : 2002 | Identical |
NBN EN 61847 : 1998 | Identical |
NF EN 61847 : 2006 | Identical |
BS EN 61847:1998 | Identical |
UNE-EN 61847:2000 | Identical |
BS EN 62127-1 : 2007 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ |
EN 80601-2-58:2015 | Medical electrical equipment - Part 2-58: Particular requirements for the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery |
I.S. EN 62127-1:2007 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007 (EQV)) |
BS EN 80601-2-58:2015 | Medical electrical equipment Particular requirements for the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery |
EN 62127-1:2007/A1:2013 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013) |
IEC 60500:2017 | Underwater acoustics - Hydrophones - Properties of hydrophones in the frequency range 1 Hz to 500 kHz |
IEC 61205:1993 | Ultrasonics - Dental descaler systems - Measurement and declaration of the output characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.