EN 62092:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz
01-10-2007
EN 62127-3:2007/A1:2013
EN 62127-1:2007/A1:2013
EN 62127-2:2007
EN 62127-3:2007
EN 62127-1:2007
18-10-2001
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 List of symbols
5 Hydrophone characteristics
5.1 General
5.2 Basic information
5.3 Hydrophone class
5.4 Sensitivity
5.5 Frequency response
5.6 Directional response
5.7 Effective radius
5.8 Dynamic range and linearity
5.9 Electric output characteristics
5.9.1 Electric output characteristics
5.9.2 Output lead configuration and ringing
resonance in cable
5.10 Information on the integral amplifier, if included
5.11 Environmental and other aspects
5.11.1 Temperature range
5.11.2 Water tightness
5.11.3 Water properties and incompatible materials
5.11.4 Other aspects
6 Relative measurements of hydrophone characteristics
6.1 General concepts
6.1.1 Relative measurement for directional response
and for comparison of sensitivity
6.1.2 Temporal waveform and frequency concepts and
hydrophone position
6.2 Measurement concepts
6.2.1 Source transducer
6.2.2 Types of measurement
6.2.3 Temporal waveform concepts
6.2.4 Hydrophone position concepts
6.3 Requirements
6.3.1 Measurement vessel and water
6.3.2 Temperature stability
6.3.3 Positional accuracy
6.3.4 Maximum hydrophone size
6.3.5 Requirements for the electronic equipment
6.3.6 Requirements with particular respect to time
delay spectrometry
7 Hydrophone calibration
Annex A (informative) Tables
Annex B (informative) Behaviour of PVDF polymer sensors in
high intensity
Annex C (informative) Hydrophone positioning in the
ultrasonic near field
Annex D (informative) Time delay spectrometry - Requirements
and a brief review of the technique
Annex E (informative) The absolute calibration of
hydrophones up to 40 MHz
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Applies to - hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic equipment; - hydrophones used for measurements made in water and in the frequency range between 15 MHz and 40 MHz; - hydrophones with or without an integral amplifier; - hydrophones with a circular piezoelectrically active element. Specifies - relevant hydrophone characteristics; - methods of determining directional response and hydrophone sensitivity based on relative or comparative measurements; and describes - absolute hydrophone calibration methods. Recommendations and references to accepted literature are made for the various relative and absolute calibration methods in the frequency range covered by this International Standard.
Committee |
CLC/SR 87
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
CEI EN 62092 : 2003 | Identical |
I.S. EN 62092:2002 | Identical |
IEC 62092:2001 | Identical |
BS EN 62092:2002 | Identical |
NBN EN 62092 : 2002 | Identical |
NEN EN IEC 62092 : 2001 | Identical |
PN EN 62092 : 2002 | Identical |
DIN EN 62092:2002-11 | Identical |
NF EN 62092 : 2006 | Identical |
UNE-EN 62092:2001 | Identical |
EN 61102:1993/A1:1994 | MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 61828:2001 | Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields |
EN 61828:2001 | Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields |
EN 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 61101:1991 | The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0.5 MHz to 15 MHz |
IEC 60866:1987 | Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz |
EN 61101:1993 | The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz |