EN 62591:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Industrial communication networks - Wireless communication network and communication profiles - WirelessHART™
16-09-2016
03-04-2021
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols, abbreviations and
conventions
4 Physical layer specification and service definition
5 Data-link layer service definition - Type 20 elements
6 Data-link layer protocol specification - Type 20 elements
7 Application layer service definition - Type 20 elements
8 Application layer protocol specification - Type 20 elements
9 Communication Profile Family 9 (HART[TM])
Annex A (normative) - Security
Annex B (normative) - Wireless procedures
Annex C (normative) - Network management
Annex D (normative) - Gateway
Annex E (normative) - Command response codes
Annex F (normative) - Common tables
Annex G (informative) - Application of publish data mode and
event commands
Annex H (informative) - Network redundancy
Annex I (informative) - Network manager implementation
Annex J (informative) - Gateway implementation
Annex K (informative) - Handheld device
Annex L (informative) - Application of WirelessHART Commands
Annex M (informative) - Regional modification for compliance with
ETSI standards
Bibliography
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
IEC 62591:2016 specifies a wireless communication network in addition to the Type 20 in IEC 61158-3-20, IEC 61158-4-20, IEC 61158-5-20, IEC 61158-6-20 and a Communication Profile CP 9/2 in addition to IEC 61784-1, CPF 9. It specifies the following:- Physical layer service definition and protocol specification,- Data-link layer service and protocol,- Application layer service and protocol,- Network management,- Security,- Communication profile,- Wireless procedures and Gateway. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- enhancements to the performance statistics using key performance indicators (KPI);- "Stale Data" detection was added (see services Read stale data setpoints, Write stale data timer and Write stale data count setpoint).;- gateway commands were added;- a Quarantined State was added;- CCA Modes were extended to be more in-line with IEEE 802.15.4;- clarifications on whitelist and blacklist management were added;- clarifications on join (e.g. only require a single neighbor) were added;- clarifications on use of join links, table management, and defaults were added;- corrections and updates were made. The reader's attention is drawn to the fact that Annex M lists all of the "in-some-country" clauses on differing practices of a less permanent nature relating to the subject of this standard.
| Committee |
CLC/TC 65X
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| Standards | Relationship |
| CEI EN 62591 : 2012 | Identical |
| NEN EN IEC 62591 : 2016 | Identical |
| NBN EN 62591 : 2016 | Identical |
| NF EN 62591 : 2016 | Identical |
| IEC 62591:2016 | Identical |
| PN EN 62591 : 2016 | Identical |
| I.S. EN 62591:2016 | Identical |
| DIN EN 62591:2014-05 (Draft) | Identical |
| ONORM OVE EN 62591 : 2017 | Identical |
| BS EN 62591:2016 | Equivalent |
| CEI EN 62591 : 2ED 2017 | Identical |
| UNE-EN 62591:2016 | Identical |
| BS EN 62591:2016 | Identical |