• EN 677:1998

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Gas-fired central heating boilers - Specific requirements for condensing boilers with a nominal heat input not exceeding 70 kW

    Available format(s): 

    Superseded date:  01-07-2014

    Language(s): 

    Published date:  17-06-1998

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Definitions
        3.1 condensing boiler
        3.2 condensate
        3.3 nominal condensing output
        3.4 maximum allowable working temperature
    4 Constructional requirements
        4.1 Materials in contact with condensate
        4.2 Removal of condensate
        4.3 Control of the combustion products temperature
        4.4 Chemical composition of the condensate
    5 Operational requirements
        5.1 General
        5.2 Verification of the nominal condensing output
        5.3 Formation of condensate
        5.4 Temperature of combustion products
        5.5 Combustion
        5.6 Efficiencies
    6 Test methods
        6.1 General
        6.2 Verification of the nominal condensing output
        6.3 Formation of condensates
        6.4 Temperature of combustion products
        6.5 Combustion
        6.6 Efficiencies
    7 Marking
        7.1 Data plate
        7.2 Instructions
    Annex A (normative) Correction for the determined efficiency
    in the low water temperature test of condensing boilers
    Annex B (informative) Special national conditions
    Annex C (informative) A-deviations
    Annex ZA (informative) Clauses of this European Standard
    addressing essential requirements or other provisions of
    EU Directives

    Abstract - (Show below) - (Hide below)

    This European standard applies to gas-fired central heating boilers, which are declared by the manufacturer to be "condensing boilers": - of types B (excluding appliances without a fan) and C, - using one or more gases corresponding to the three gas families, and - for which the nominal heat input is less than or equal to 70 kW. This European standard only covers type testing. This European standard completes or modifies the standards EN 297, prEN 483 and EN 625, hereafter called "boiler standards". It specifies supplementary requirements for condensing boilers.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 109
    Development Note Superseded by EN 15502-2-2 but remains current until 2017. (08/2014)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 50165:1997 Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements
    00/242179 DC : DRAFT MAY 2000 IEC 60335-2-102, ED. 1 - PARTICULAR REQUIREMENTS FOR ELECTRICALLY SUPPLIED APPLIANCES WITH NON-ELECTRIC HEATING SOURCES FOR HOUSEHOLD AND SIMILAR USE
    05/30129922 DC : DRAFT FEB 2005 EN 15036-2 - HEATING BOILERS - TEST REGULATIONS FOR THE AIRBORNE NOISE EMISSIONS FROM HEAT GENERATORS - PART 2: FLUE GAS NOISE EMISSIONS AT THE OUTLET OF THE HEAT GENERATOR
    PREN 15316-4-1 : DRAFT 2014 HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS)
    ISO 13675:2013 Heating systems in buildings Method and design for calculation of the system energy performance Combustion systems (boilers)
    S.R. CEN/TR 16787:2014 INDUSTRIAL GAS INSTALLATION - GUIDELINE
    BS EN 297:1994 Gas-fired central heating boilers. Type B11 and B11BS boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW
    CEN/TR 16787:2014 Industrial Gas Installation - Guideline
    14/30311499 DC : 0 BS EN 15316-4-1 - HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS)
    DIN EN 15316-3-3:2008-06 HEATING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 3-3: DOMESTIC HOT WATER SYSTEMS, GENERATION
    BS EN 15316-3-3:2007 Heating systems in buildings. Method for calculation of system energy requirements and system efficiencies Domestic hot water systems, generation
    PREN 50465 : DRAFT 2011 GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW
    PD CEN/TR 16787:2014 Industrial Gas Installation. Guideline
    05/30137893 DC : 0 EN 15316-3-3 - HEATING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 3.3: DOMESTIC HOT WATER SYSTEMS, GENERATION
    EN 15316-3-3:2007 Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 3-3: Domestic hot water systems, generation
    EN 297:1994/A2:1996/AC:2006 GAS-FIRED CENTRAL HEATING BOILERS - TYPE B[11] AND B[11BS] BOILERS FITTED WITH ATMOSPHERIC BURNERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW
    12/30239784 DC : 0 BS ISO 13675 - HEATING AND COOLING SYSTEMS IN BUILDINGS - METHOD AND DESIGN FOR CALCULATION OF THE SYSTEM ENERGY PERFORMANCE - COMBUSTION SYSTEMS (BOILERS)
    11/30249911 DC : 0 BS EN 50465 - GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW
    BS ISO 13675:2013 Heating systems in buildings. Method and design for calculation of the system energy performance. Combustion systems (boilers)
    I.S. EN 15316-3-3:2007 HEATING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 3-3: DOMESTIC HOT WATER SYSTEMS, GENERATION

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 297:1994/A2:1996/AC:2006 GAS-FIRED CENTRAL HEATING BOILERS - TYPE B[11] AND B[11BS] BOILERS FITTED WITH ATMOSPHERIC BURNERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW
    EN 437:2003+A1:2009 Test gases - Test pressures - Appliance categories
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective