• EN IEC 60099-8:2018

    Current The latest, up-to-date edition.

    Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

    Available format(s): 

    Language(s): 

    Published date:  09-02-2018

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Identification and classification
    5 Standard ratings and service conditions
    6 Requirements
    7 General testing procedure
    8 Type tests
    9 Routine tests
    10 Acceptance tests
    Annex A (informative) - Example of a test circuit for
            the follow current interrupting test
    Annex B (normative) - Mechanical considerations
    Annex C (normative) - Special service conditions
    Bibliography
    Annex ZA (normative) - Normative references
             to international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    NEW!IEC 60099-8:2017 is available as IEC 60099-8:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers. This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document:

    - switching impulse spark-over voltage;

    - residual voltage at steep current and switching current impulse;

    - thermal stability;

    - long-duration current impulse withstand duty;

    - power-frequency voltage versus time characteristics of an arrester;

    - disconnector test;

    - aging duties by power-frequency voltage.

    Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:

    The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced.

    - Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA.

    - Definitions for new terms have been added

    - A number of NOTES in Ed. 1 have been converted to normative requirements



    Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages

    General Product Information - (Show below) - (Hide below)

    Committee CLC/SR 37
    Development Note Supersedes & Redesignates EN 60099-8. (03/2018)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
    ISO 4892-1:2016 Plastics Methods of exposure to laboratory light sources Part 1: General guidance
    EN ISO 4287:1998/A1:2009 GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - SURFACE TEXTURE: PROFILE METHOD - TERMS, DEFINITIONS AND SURFACE TEXTURE PARAMETERS
    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    ISO 4287:1997 Geometrical Product Specifications (GPS) — Surface texture: Profile method — Terms, definitions and surface texture parameters
    EN ISO 4892-1:2016 Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016)
    EN ISO 4892-3:2016 Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps (ISO 4892-3:2016)
    IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
    EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
    EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
    ISO 4892-3:2016 Plastics Methods of exposure to laboratory light sources Part 3: Fluorescent UV lamps
    ISO 3274:1996 Geometrical Product Specifications (GPS) — Surface texture: Profile method — Nominal characteristics of contact (stylus) instruments
    ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
    EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
    EN ISO 4892-2:2013 Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2:2013)
    EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective