EN ISO 10121-1:2014
Current
The latest, up-to-date edition.
Test method for assessing the performance of gas-phase air cleaning media and devices for general ventilation - Part 1: Gas-phase air cleaning media (ISO 10121-1:2014)
16-04-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Testing of different GPACM configurations
6 Test sequence
7 Validation of test setup
8 Evaluation and report
9 Safety features
Annex A (normative) - Test equipment requirements,
equipment validation and routine operation
Annex B (informative) - Challenge gases, generation
sources and analysis techniques
Annex C (informative) - Design of a media test stand
Annex D (normative) - Normative sampling procedures
and test parameters for different GPACM
Bibliography
ISO 10121-1:2014 aims to provide an objective laboratory test method, a suggested apparatus, normative test sections and normative tests for evaluation of three different solid gas-phase air cleaning media (GPACM) or GPACM configurations for use in gas-phase air cleaning devices intended for general filtration applications. ISO 10121-1:2014 is specifically intended for challenge testing and not for general material evaluation or pore system characterization. The three different types of GPACM identified in ISO 10121-1:2014 are GPACM-LF (particles of different shape and size intended for e.g. Loose Fill applications), GPACM-FL (FLat sheet fabric intended for e.g. flat one layer, pleated or bag type devices) and GPACM-TS (three dimensional structures that are many times thicker than flat sheet and e.g. used as finished elements in a device). The tests are conducted in an air stream and the GPACM configurations are challenged with test gases under steady-state conditions. Since elevated gas challenge concentrations (relative to general ventilation applications) are used, test data should be used to compare GPACM within the same configuration and not for the purpose of predicting performance in a real situation. It is also not implied that different GPACM configurations can be directly compared. The primary intention is to be able to compare like GPACM configurations to like, not between GPACM configurations. Testing of complete devices is described in ISO 10121‑2.To ensure objectivity for test equipment suppliers, no specific design of the test apparatus is defined: an example is illustrated in an annex. Instead normative demands for media sample holder design, apparatus properties and validation tests are specified.
Committee |
CEN/TC 195
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN ISO 10121-1 : 2014 | Identical |
NEN EN ISO 10121-1 : 2014 | Identical |
ISO 10121-1:2014 | Identical |
BS EN ISO 10121-1:2014 | Identical |
I.S. EN ISO 10121-1:2014 | Identical |
UNI EN ISO 10121-1 : 2014 | Identical |
DIN EN ISO 10121-1:2015-10 | Identical |
SN EN ISO 10121-1:2014 | Identical |
NS EN ISO 10121-1 : 2014 | Identical |
UNE-EN ISO 10121-1:2015 | Identical |
PN EN ISO 10121-1 : 2014 | Identical |
NBN EN ISO 10121-1 : 2014 | Identical |
EN 16798-3:2017 | Energy performance of buildings - Ventilation for buildings - Part 3: For non-residential buildings - Performance requirements for ventilation and room-conditioning systems (Modules M5-1, M5-4) |
DIN EN 16798-3:2017-11 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 3: FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4) |
I.S. EN 16798-3:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 3: FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4) |
ISO 29464:2017 | Cleaning of air and other gases — Terminology |
ASHRAE 145.2 : 2011 | LABORATORY TEST METHOD FOR ASSESSING THE PERFORMANCE OF GAS-PHASE AIR-CLEANING SYSTEMS: AIR-CLEANING DEVICES |
EN 779:2012 | Particulate air filters for general ventilation - Determination of the filtration performance |
ASHRAE 145.1 : 2015 | LABORATORY TEST METHOD FOR ASSESSING THE PERFORMANCE OF GAS-PHASE AIR-CLEANING SYSTEMS: LOOSE GRANULAR MEDIA |
ISO 29463-1:2017 | High efficiency filters and filter media for removing particles from air — Part 1: Classification, performance, testing and marking |
ISO 10121-2:2013 | Test methods for assessing the performance of gas-phase air cleaning media and devices for general ventilation — Part 2: Gas-phase air cleaning devices (GPACD) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.