• EN ISO 10993-6:2016

    Current The latest, up-to-date edition.

    Biological evaluation of medical devices - Part 6: Tests for local effects after implantation (ISO 10993-6:2016)

    Available format(s): 

    Language(s): 

    Published date:  14-12-2016

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Common provisions for implantation test methods
    5 Test methods, general aspects
    6 Test report
    Annex A (normative) - Test methods for
            implantation in subcutaneous tissue
    Annex B (normative) - Test method for implantation
            in muscle
    Annex C (normative) - Test method for implantation
            in bone
    Annex D (normative) - Test method for implantation
            in brain tissue
    Annex E (informative) - Examples of evaluation of local
            biological effects after implantation
    Bibliography
    Annex ZA (informative) - Relationship between this
             European Standard and the essential
             requirements of Directive 93/42/EEC
             [OJ L 169] aimed to be covered
    Annex ZB (informative) - Relationship between this
             European Standard and the essential
             requirements of Directive 90/385/EEC
             [OJ L 189] aimed to be covered

    Abstract - (Show below) - (Hide below)

    ISO 10993-6:2016 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices.ISO 10993-6:2016 applies to materials that are- solid and non-absorbable,- non-solid, such as porous materials, liquids, gels, pastes, and particulates, and- degradable and/or absorbable, which may be solid or non-solid.The test sample is implanted into a site and animal species appropriate for the evaluation of the biological safety of the material. These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical or functional loading. This part of ISO 10993 can also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining might have been breached, in order to evaluate local tissue responses.The local effects are evaluated by a comparison of the tissue response caused by a test sample to that caused by control materials used in medical devices whose clinical acceptability and biocompatibility characteristics have been established. The objective of the test methods is to characterize the history and evolution of the tissue response after implantation of a medical device/biomaterial including final integration or absorption/degradation of the material. In particular for degradable/absorbable materials, the degradation characteristics of the material and the resulting tissue response should be determined.ISO 10993-6:2016 does not deal with systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the long-term implantation studies intended for evaluation of local biological effects might provide insight into some of these properties. Systemic toxicity studies conducted by implantation might satisfy the requirements of this part of ISO 10993. When conducting combined studies for evaluating local effects and systemic effects, the requirements of both standards is to be fulfilled.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 206
    Development Note Supersedes EN 30993-6. (05/2007)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN ISO 7198:2017 CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR PROSTHESES - TUBULAR VASCULAR GRAFTS AND VASCULAR PATCHES (ISO 7198:2016)
    UNE-EN ISO 16672:2016 Ophthalmic implants - Ocular endotamponades (ISO 16672:2015)
    EN ISO 15798:2013/A1:2017 OPHTHALMIC IMPLANTS - OPHTHALMIC VISCOSURGICAL DEVICES (ISO 15798:2013/AMD 1:2017)
    BS EN ISO 25539-1:2017 Cardiovascular implants. Endovascular devices Endovascular prostheses
    I.S. EN ISO 15798:2013 OPHTHALMIC IMPLANTS - OPHTHALMIC VISCOSURGICAL DEVICES (ISO 15798:2013)
    I.S. EN ISO 25539-1:2017 CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017)
    EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
    UNE-EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
    BS EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems. Vascular prostheses. Tubular vascular grafts and vascular patches

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 5832-1:2016 Implants for surgery — Metallic materials — Part 1: Wrought stainless steel
    ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
    ISO 10993-16:2017 Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables
    ASTM F 1983 : 2014 : REDLINE Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications
    EN ISO 10993-2:2006 Biological evaluation of medical devices - Part 2: Animal welfare requirements (ISO 10993-2:2006)
    ISO 5832-6:1997 Implants for surgery Metallic materials Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy
    ISO 5832-5:2005 Implants for surgery Metallic materials Part 5: Wrought cobalt-chromium-tungsten-nickel alloy
    ISO 5832-3:2016 Implants for surgery Metallic materials Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
    ISO 10993-2:2006 Biological evaluation of medical devices — Part 2: Animal welfare requirements
    ISO 7405:2008 Dentistry Evaluation of biocompatibility of medical devices used in dentistry
    EN ISO 10993-4:2017 Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017)
    ISO 5832-8:1997 Implants for surgery Metallic materials Part 8: Wrought cobalt-nickel-chromium-molybdenum- tungsten-iron alloy
    ISO 5832-4:2014 Implants for surgery — Metallic materials — Part 4: Cobalt-chromium-molybdenum casting alloy
    ISO 6474-1:2010 Implants for surgery Ceramic materials Part 1: Ceramic materials based on high purity alumina
    ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
    ISO 10993-12:2012 Biological evaluation of medical devices Part 12: Sample preparation and reference materials
    ISO 5834-2:2011 Implants for surgery Ultra-high-molecular-weight polyethylene Part 2: Moulded forms
    ASTM F 748 : 2016 : REDLINE Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices
    ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
    ISO 5832-2:1999 Implants for surgery Metallic materials Part 2: Unalloyed titanium
    ISO 5832-7:2016 Implants for surgery — Metallic materials — Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy
    ISO 10993-9:2009 Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products
    EN ISO 10993-12:2012 Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012)
    ISO 11979-5:2006 Ophthalmic implants Intraocular lenses Part 5: Biocompatibility
    EN ISO 10993-1:2009/AC:2010 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009/COR 1:2010)
    ISO 6474-2:2012 Implants for surgery Ceramic materials Part 2: Composite materials based on a high-purity alumina matrix with zirconia reinforcement
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective