• EN ISO 11140-4:2007

    Current The latest, up-to-date edition.

    Sterilization of health care products - Chemical indicators - Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration (ISO 11140-4:2007)

    Available format(s): 

    Language(s): 

    Published date:  14-03-2007

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 Indicator system format
    6 Performance requirements
    7 Packaging and labelling
    8 Quality assurance
    Annex A (normative) Determination of indicator strength
            during and after steam sterilization
    Annex B (normative) Standard test cycles
    Annex C (normative) Estimation of visual difference
            between colour of the substrate and of the
            changed or unchanged indicator system by
            determination of relative reflectance density
    Annex D (normative) Determination of uniform colour change
            on exposure to saturated steam
    Annex E (normative) Determination of equivalence of the
            alternative indicator to the Bowie and Dick test
    Annex F (normative) Determination of reproducibility of
            fail conditions created in a standard test pack
            by air injection, air leak and retained air systems
    Annex G (normative) Determination of indicator colour change
            on exposure to dry heat
    Annex H (normative) Determination of shelf life of product
    Annex I (normative) Accelerated ageing of test samples
    Annex J (normative) Steam exposure apparatus and steam for
            test purposes
    Annex K (normative) Standard test pack
    Annex L (normative) Air injection system
    Bibliography

    Abstract - (Show below) - (Hide below)

    ISO 11140-4:2007 specifies the performance for a Class 2 indicator to be used as an alternative to the Bowie and Dick-type test for steam sterilizers for wrapped health care goods (instruments, etc. and porous loads).An indicator complying with ISO 11140-4:2007 incorporates a specified material which is used as a test load. This test load may, or may not, be re-usable. ISO 11140-4:2007 does not specify requirements for the test load, but specifies the performance of the indicator in combination with the test load with which it is intended to be used. The indicator specified in ISO 11140-4:2007 is intended to identify poor steam penetration but does not necessarily indicate the cause of this poor steam penetration.This part of ISO 11140-4:2007 does not include test methods to establish the suitability of these indicators for use in sterilizers in which the air removal stage does not include evacuation below atmospheric pressure.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 102
    Development Note Supersedes EN 867-4. (03/2007)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 15424:2007 STERILIZATION OF MEDICAL DEVICES - LOW TEMPERATURE STEAM AND FORMALDEHYDE - REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES
    PREN 285 : DRAFT 2013 STERILIZATION - STEAM STERILIZERS - LARGE STERILIZERS
    EN 285:2015 Sterilization - Steam sterilizers - Large sterilizers
    BS EN 15424:2007 Sterilization of medical devices. Low temperature steam and formaldehyde. Requirements for development, validation and routine control of a sterilization process for medical devices
    13/30278676 DC : 0 BS EN 285 - STERILIZATION - STEAM STERILIZERS - LARGE STERILIZERS
    VDI 6300 Blatt 1:2016-05 Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities
    I.S. EN 285:2015 STERILIZATION - STEAM STERILIZERS - LARGE STERILIZERS
    DIN EN 285:2016-05 Sterilization - Steam sterilizers - Large sterilizers
    STANAG 2906 : 2015 ESSENTIAL PHYSICAL REQUIREMENTS AND PERFORMANCE CHARACTERISTICS OF FIELD TYPE HIGH PRESSURE STEAM STERILIZERS
    BS EN 285:2015 Sterilization. Steam sterilizers. Large sterilizers
    EN 15424:2007 Sterilization of medical devices - Low temperature steam and formaldehyde - Requirements for development, validation and routine control of a sterilization process for medical devices
    UNE-EN 285:2016 Sterilization - Steam sterilizers - Large sterilizers

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 5636-3:2013 Paper and board — Determination of air permeance (medium range) — Part 3: Bendtsen method
    ISO 15882:2008 Sterilization of health care products — Chemical indicators — Guidance for selection, use and interpretation of results
    EN 285:2015 Sterilization - Steam sterilizers - Large sterilizers
    ISO 11140-3:2007 Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test
    ISO 187:1990 Paper, board and pulps — Standard atmosphere for conditioning and testing and procedure for monitoring the atmosphere and conditioning of samples
    ISO 11140-1:2014 Sterilization of health care products Chemical indicators Part 1: General requirements
    ISO 5-4:2009 Photography and graphic technology Density measurements Part 4: Geometric conditions for reflection density
    ISO 5-3:2009 Photography and graphic technology Density measurements Part 3: Spectral conditions
    IEC 60751:2008 Industrial platinum resistance thermometers and platinum temperature sensors
    ISO 5-1:2009 Photography and graphic technology Density measurements Part 1: Geometry and functional notation
    ISO 9001:2015 Quality management systems — Requirements
    ISO/CIE 10526:1999 CIE standard illuminants for colorimetry
    ISO 2248:1985 Packaging Complete, filled transport packages Vertical impact test by dropping
    ISO 10012-1:1992 Quality assurance requirements for measuring equipment Part 1: Metrological confirmation system for measuring equipment
    ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective