EN ISO 11732:2005
Current
The latest, up-to-date edition.
Water quality - Determination of ammonium nitrogen - Method by flow analysis (CFA and FIA) and spectrometric detection (ISO 11732:2005)
01-02-2005
Foreword
Introduction
1 Scope
2 Normative references
3 Determination of ammonium nitrogen by flow injection
analysis (FIA) and spectrometric detection
4 Determination of ammonium nitrogen by continuous
flow analysis (CFA) and spectrometric detection
5 Calculation
6 Precision
7 Test report
Annex A (informative) Examples of flow analysis systems
Annex B (informative) Precision data
Bibliography
ISO 11732:2005 specifies methods suitable for the determination of ammonium nitrogen in various types of waters (such as ground, drinking, surface, and waste waters) in mass concentrations ranging from 0,1 mg/l to 10 mg/l (in the undiluted sample), applying either FIA or CFA. In particular cases, the range of application may be adapted by varying the operating conditions.
| Committee |
CEN/TC 230
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Current
|
| Standards | Relationship |
| BS 6068-2.93(2005) : 2005 | Identical |
| ISO 11732:2005 | Identical |
| NEN EN ISO 11732 : 2005 | Identical |
| PN EN ISO 11732 : 2007 | Identical |
| BS EN ISO 11732:2005 | Identical |
| NS EN ISO 11732 : 2ED 2005 | Identical |
| I.S. EN ISO 11732:2005 | Identical |
| NBN EN ISO 11732 : 2005 | Identical |
| SS-EN ISO 11732:2005 | Identical |
| NF EN ISO 11732 : 2005 | Identical |
| UNE-EN ISO 11732:2005 | Identical |
| DIN EN ISO 11732:2005-05 | Identical |
| 16/30329428 DC : 0 | BS EN 12566-6 - SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 6: PREFABRICATED TREATMENT UNITS FOR SEPTIC TANK EFFLUENT |
| 03/106266 DC : DRAFT APR 2003 | BS EN 14671 - CHARACTERISATION OF SLUDGES - PRE-TREATMENT FOR THE DETERMINATION OF EXTRACTABLE AMMONIA USING 2 MOL/L POTASSIUM CHLORIDE |
| I.S. EN 12566-7:2016 | SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 7: PREFABRICATED TERTIARY TREATMENT UNITS |
| BS EN 12566-6:2013 | Small wastewater treatment systems for up to 50 PT Prefabricated treatment units for septic tank effluent |
| I.S. EN 12566-3:2016 | SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 3: PACKAGED AND/OR SITE ASSEMBLED DOMESTIC WASTEWATER TREATMENT PLANTS |
| EN 12566-6:2016 | Small wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units for septic tank effluent |
| CEN/TS 16177:2012 | Sludge, treated biowaste and soil - Extraction for the determination of extractable ammonia, nitrate and nitrite |
| EN 12566-3:2016 | Small wastewater treatment systems for up to 50 PT - Part 3: Packaged and/or site assembled domestic wastewater treatment plants |
| EN 12566-7:2016 | Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units |
| XP CEN/TS 16177 : 2012 XP | SLUDGE, TREATED BIOWASTE AND SOIL - EXTRACTION FOR THE DETERMINATION OF EXTRACTABLE AMMONIA, NITRATE AND NITRITE |
| 10/30233988 DC : 0 | BS EN 16192 - CHARACTERIZATION OF WASTE - ANALYSIS OF ELUATES |
| PREN 12566-6 : DRAFT 2015 | SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 6: PREFABRICATED TREATMENT UNITS FOR SEPTIC TANK EFFLUENT |
| 17/30348303 DC : 0 | BS EN 17087 - CONSTRUCTION PRODUCTS - ASSESSMENT OF RELEASE OF DANGEROUS SUBSTANCES - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE FOR TESTING OF RELEASE AND ANALYSIS OF CONTENT |
| DIN EN 13370:2003-09 | CHARACTERIZATION OF WASTE - ANALYSIS OF ELUATES - DETERMINATION OF AMMONIUM, AOX, CONDUCTIVITY, HG, PHENOL INDEX, TOC, CN[-] EASILY LIBERATABLE, F[-] |
| I.S. EN 15002:2015 | CHARACTERIZATION OF WASTE - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE |
| VDI 3878:2017-09 | Stationary source emissions - Measurement of ammonia (and gaseous ammonium compounds) - Manual method |
| VDI 3869 Blatt 4:2012-03 | Measurement of ammonia in ambient air - Sampling with diffusive samplers - Photometric or ion chromatographic analysis |
| VDI 3794 Blatt 2:2013-07 | Determination of depositon fluxes of ambient air pollutants - Determination of the deposition flux of ammonia and ammonium compounds by means of the IRMA method |
| VDI 4320 Blatt 3:2017-01 | Measurement of atmospheric depositions - Determination of the deposition of water-soluble anions and cations - Sampling with bulk- and wet only-collectors |
| VDI 3455:2013-08 | Emission control - High-volume car body painting plants |
| BS EN 16192:2011 | Characterization of waste. Analysis of eluates |
| DIN EN 16192:2012-02 | Characterization of waste - Analysis of eluates |
| 01/107111 DC : DRAFT SEP 2001 | BS EN 12566-3 - SMALL WASTEWATER TREATMENT SYSTEMS UP TO 50 PT - PACKAGED AND/OR SITE ASSEMBLED DOMESTIC WASTEWATER TREATMENT PLANTS |
| I.S. EN 16192:2011 | CHARACTERIZATION OF WASTE - ANALYSIS OF ELUATES |
| 16/30329422 DC : 0 | BS EN 12566-7 - SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 7: PREFABRICATED TERTIARY TREATMENT UNITS |
| I.S. EN 13370:2003 | CHARACTERIZATION OF WASTE - ANALYSIS OF ELUATES - DETERMINATION OF AMMONIUM, AOX, CONDUCTIVITY, HG, PHENOL INDEX, TOC, EASILY LIBERATABLE CN[-], F[-] |
| DIN EN 16169:2012-11 | SLUDGE, TREATED BIOWASTE AND SOIL - DETERMINATION OF KJELDAHL NITROGEN |
| BS EN 12566-7:2013 | Small wastewater treatment systems for up to 50 PT Prefabricated tertiary treatment units |
| PREN 12566-7 : DRAFT 2015 | SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 7: PREFABRICATED TERTIARY TREATMENT UNITS |
| NF EN 16192 : 2012 | CHARACTERIZATION OF WASTE - ANALYSIS OF ELUATES |
| 13/30291099 DC : 0 | BS EN 15002 - CHARACTERIZATION OF WASTE - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE |
| BS EN 14671:2006 | Characterization of sludges. Pre-treatment for the determination of extractable ammonia using 2 mol/l potassium chloride |
| BS EN 12566-3 : 2005 | SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 3: PACKAGED AND/OR SITE ASSEMBLED DOMESTIC WASTEWATER TREATMENT PLANTS |
| BS EN 13370:2003 | Characterization of waste. Analysis of eluates. Determination of Ammonium, AOX, conductivity, Hg, phenol index, TOC, easily liberatable CN<sup>-</sup>, F<sup>-</sup> |
| DIN EN 15002:2015-07 | CHARACTERIZATION OF WASTE - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE |
| EN 16169:2012 | Sludge, treated biowaste and soil - Determination of Kjeldahl nitrogen |
| EN 15002:2015 | Characterization of waste - Preparation of test portions from the laboratory sample |
| EN 14671:2006 | Characterization of sludges - Pre-treatment for the determination of extractable ammonia using 2 mol/l potassium chloride |
| 16/30329416 DC : 0 | BS EN 12566-3 - SMALL WASTEWATER TREATMENT SYSTEMS UP TO 50 PT - PART 3: PACKAGED AND/OR SITE ASSEMBLED DOMESTIC WASTEWATER TREATMENT PLANTS |
| BS EN 16169:2012 | Sludge, treated biowaste and soil. Determination of Kjeldahl nitrogen |
| DD ENV 13370:2001 | Characterization of waste. Analysis of eluates. Determination of Ammonium-N, AOX, conductivity, Hg, phenol index, TOC, CN<sup>-</sup> easily liberatable, F<sup>-</sup> |
| 04/30116791 DC : DRAFT JUL 2004 | BS EN 15002 - CHARACTERISATION OF WASTE - PREPARATION OF TEST PORTIONS FROM LABORATORY SAMPLE |
| 08/30187745 DC : 0 | BS EN 12566-6 - SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 6: PREFABRICATED TREATMENT UNITS FOR SEPTIC TANK EFFLUENT |
| S.R. CEN/TS 16177:2012 | SLUDGE, TREATED BIOWASTE AND SOIL - EXTRACTION FOR THE DETERMINATION OF EXTRACTABLE AMMONIA, NITRATE AND NITRITE |
| I.S. EN 12566-6:2016 | SMALL WASTEWATER TREATMENT SYSTEMS FOR UP TO 50 PT - PART 6: PREFABRICATED TREATMENT UNITS FOR SEPTIC TANK EFFLUENT |
| I.S. EN 16169:2012 | SLUDGE, TREATED BIOWASTE AND SOIL - DETERMINATION OF KJELDAHL NITROGEN |
| BS EN 15002:2015 | Characterization of waste. Preparation of test portions from the laboratory sample |
| DIN EN 14671:2006-09 | Characterization of sludges - Pre-treatment for the determination of extractable ammonia using 2 mol/l potassium chloride |
| EN 13370:2003 | Characterization of waste - Analysis of eluates - Determination of Ammonium, AOX, conductivity, Hg, phenol index, TOC, easily liberatable CN-, F- |
| EN 16192:2011 | Characterization of waste - Analysis of eluates |
| UNE-EN 16192:2012 | Characterization of waste - Analysis of eluates |
| UNE-EN 12566-7:2017 | Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units |
| UNE-EN 12566-6:2017 | Small wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units for septic tank effluent |
| UNE-EN 12566-3:2017 | Small wastewater treatment systems for up to 50 PT - Part 3: Packaged and/or site assembled domestic wastewater treatment plants |
| UNE-EN 15002:2015 | Characterization of waste - Preparation of test portions from the laboratory sample |
| ISO 5667-2:1991 | Water quality — Sampling — Part 2: Guidance on sampling techniques |
| ISO 5667-3:2012 | Water quality — Sampling — Part 3: Preservation and handling of water samples |
| ISO 5667-1:2006 | Water quality — Sampling — Part 1: Guidance on the design of sampling programmes and sampling techniques |
| ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
| ISO 8466-1:1990 | Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 1: Statistical evaluation of the linear calibration function |
| ISO 7150-2:1986 | Water quality — Determination of ammonium — Part 2: Automated spectrometric method |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.