EN ISO 11810-2:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lasers and laser-related equipment - Test method and classification for the laser-resistance of surgical drapes and/or patient-protective covers - Part 2: Secondary ignition (ISO 11810-2:2007)
01-12-2015
04-03-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test methods
5 Classification
6 Test Report
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential
Requirements of EU Directive
93/42/EC
ISO 11810-2:2007 is applicable to disposable and re-usable, as well as woven and non-woven materials used as surgical drapes and/or patient protective covers which claim to be laser-resistant.The purpose of ISO 11810-2:2007 is to provide a standardized method for testing and classifying surgical drapes and/or patient protective covers with respect to laser-induced hazards. An appropriate classification system is given. It is not the purpose of ISO 11810-2:2007 to serve as a general fire safety specification. ISO 11810-2:2007 is limited to testing the secondary ignition of materials that are rated I1 or I2 from ISO 11810-1.All materials reflect portions of the beam and it is necessary for the user to decide whether specular reflection may be a hazard. This measurement, however, is not covered in ISO 11810-2:2007.
Committee |
CEN/TC 123
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN EN ISO 11810-2:2009-07 | Identical |
NBN EN ISO 11810-2 : 2009 | Identical |
BS EN ISO 11810-2:2009 | Identical |
I.S. EN ISO 11810-2:2009 | Identical |
NEN EN ISO 11810-2 : 2009 | Identical |
PN EN ISO 11810-2 : 2010 | Identical |
UNE-EN ISO 11810-2:2010 | Identical |
NS EN ISO 11810-2 : 2009 | Identical |
NF EN ISO 11810-2 : 2009 | Identical |
UNI EN ISO 11810-2 : 2009 | Identical |
ISO 11810-2:2007 | Identical |
SN EN ISO 11810-2 : 2009 | Identical |
I.S. EN 16844:2017 | AESTHETIC MEDICINE SERVICES - NON-SURGICAL MEDICAL PROCEDURES |
I.S. EN 16844:2017+A2:2019 | Aesthetic medicine services - Non-surgical medical treatments |
I.S. EN 13795:2011 | SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
13/30278952 DC : 0 | BS EN 16372 - AESTHETIC SURGERY AND AESTHETIC NON-SURGICAL MEDICAL SERVICES |
BS EN 13795:2011+A1:2013 | Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment. General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels |
15/30317874 DC : 0 | BS EN 16844 - AESTHETIC MEDICINE SERVICES - NON-SURGICAL MEDICAL PROCEDURES |
UNE-EN 16372:2015 | Aesthetic surgery services |
12/30254927 DC : 0 | BS EN 16372 - AESTHETIC SURGERY SERVICES |
UNI EN 13795 : 2013 | SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
I.S. EN 16372:2014 | AESTHETIC SURGERY SERVICES |
EN 16844:2017 | Aesthetic medicine services - Non-surgical medical treatments |
09/30190221 DC : 0 | BS EN 13795 - SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES, FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
UNE-EN 13795:2011 | Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels |
EN 16372:2014 | Aesthetic surgery services |
EN 13795:2011+A1:2013 | Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels |
DIN EN 13795:2013-10 | SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
BS EN 16372:2014 | Aesthetic surgery services |
BS EN 16844 : 2017 | AESTHETIC MEDICINE SERVICES - NON-SURGICAL MEDICAL TREATMENTS |
EN 13795-1:2002+A1:2009 | Surgical drapes, gowns and clean air suits, used as medical devices, for patients, clinical staff and equipment - Part 1: General requirements for manufacturers, processors and products |
ISO 80000-4:2006 | Quantities and units Part 4: Mechanics |
ISO 2947:1973 | Textiles — Integrated conversion table for replacing traditional yarn numbers by rounded values in the Tex System |
ISO 11146-1:2005 | Lasers and laser-related equipment Test methods for laser beam widths, divergence angles and beam propagation ratios Part 1: Stigmatic and simple astigmatic beams |
ISO 6940:2004 | Textile fabrics — Burning behaviour — Determination of ease of ignition of vertically oriented specimens |
ISO 9773:1998 | Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source |
IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
IEC 60601-2-22:2007+AMD1:2012 CSV | Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
EN 14079:2003 | Non-active medical devices - Performance requirements and test methods for absorbent cotton gauze and absorbent cotton and viscose gauze |
ISO 11810-1:2005 | Lasers and laser-related equipment Test method and classification for the laser resistance of surgical drapes and/or patient protective covers Part 1: Primary ignition and penetration |
ISO 4880:1997 | Burning behaviour of textiles and textile products — Vocabulary |
ISO 139:2005 | Textiles — Standard atmospheres for conditioning and testing |
ISO 1144:2016 | Textiles Universal system for designating linear density (Tex System) |
ISO 11145:2016 | Optics and photonics Lasers and laser-related equipment Vocabulary and symbols |
ISO 6941:2003 | Textile fabrics — Burning behaviour — Measurement of flame spread properties of vertically oriented specimens |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.